Detailed Product Description
Built in AVR and Charger
Off mode charging
Overload protect
Line interactive UPS
400va-1500va nobreaks ups
N series line interactive ups nobreaks/offline UPS is with LED indicators display and built in AVR, from 400VA to 1500VA, competitive price, smart size and low power consumption. Mainly used for computer, PCs, computer peripherals.
Offline PC UPS with AVR 400VA-1500VA off mode charging RS232 RJ45 USB ports
Main Features:
Equipped with Boost and Buck AVR to stabilize input voltage.
Wide input voltage range, AVR function.
Built in DC start function enables UPS to start up without AC power supply.
SMD technology to save space, light weight.
Intelligent battery management.
Smart RS-232 or USB communication port with free download software from Internet.
Modem/Line Surge Protection: RJ11/RJ12/RJ45.
Overload/ Over charge/ Short-circuit protection.
Low battery alarm, LED status display.
IEC cables connect with PC.
Auto restart while AC recovery.
Technical Specification for N series line interactive UPS with AVR:
MODEL |
N400 |
N500 |
N650 |
N800 |
N1000 |
N1200 |
N1500 |
Nominal Capacity |
400VA/240W |
500VA/300W |
650VA/390W |
800VA/480W |
1000VA/600W |
1200VA/720W |
1500VA/900W |
Input |
Voltage Range |
145~280VAC/ 80VAC-150VAC |
Frequency |
50/60Hz |
Output |
Voltage Range |
220VAC/120VAC ± 10% |
Frequency |
50Hz/60Hz ± 5% |
Output Waveform |
Square Wave |
Transfer time |
< 10ms |
Battery |
Type |
Sealed free maintenance lead acid battery |
Capacity |
12V, 4AH *1PCS |
12V, 7AH *1PCS |
12V, 7AH *1PCS |
12V, 9AH *1PCS |
12V, 7AH *2PCS |
12V, 9AH *2PCS |
12V, 9AH *2PCS |
Recharge Time |
8 hrs to 90% of capacity full load discharge |
Protection |
Auto protect |
Back-up time( Full load ) |
3~5 min |
5~7 min |
7~10 min |
6~8 min |
5~7 min |
8~10 min |
10-12min |
Function |
Auto voltage output on AC mode, Auto shutoff if short circuit or overload |
DB-9 port, communication software |
Optional RS232, RJ11, RJ45, USB |
Protection |
AC mode |
Fuse |
Short circuit |
AC |
Fuse |
Invert mode |
Auto protect |
Alarm |
Alarm |
Battery discharge |
Alarm beeps every four seconds |
Low battery voltage |
Alarm beeps every second |
Overload |
Alarm beeps continuously |
Indicator light |
Auto adjust |
Green lighting: AC mode |
Battery Discharge |
Red lighting: Battery mode |
Environment |
Operating temperature |
0C~40C |
Operating Humidity |
0-90% non-condensing |
Noise |
< 35dB(1 meter distance) |
UPS Dimension(L× W× H)mm |
325*90*150 |
335*100*150 |
345*125*190 |
Net weight (N. W) |
4.5KG |
6.5KG |
6.8KG |
7.5KG |
11KG |
12KG |
13KG |
Gross weight (G. W) |
4.7KG |
6.7KG |
7KG |
7.7KG |
11.3KG |
12.3KG |
13.3KG |