• 3000W 5000W 6000W Pure Sine Wave Inverter
  • 3000W 5000W 6000W Pure Sine Wave Inverter
  • 3000W 5000W 6000W Pure Sine Wave Inverter
  • 3000W 5000W 6000W Pure Sine Wave Inverter
  • 3000W 5000W 6000W Pure Sine Wave Inverter
  • 3000W 5000W 6000W Pure Sine Wave Inverter

3000W 5000W 6000W Pure Sine Wave Inverter

Nature of Source Flow: Active Inverter
Certification: ISO9001, CE, FCC
Output Power: 3kw 5kw 6kw
Grid Type: off-Grid Inverter
Output Type: Single or Dual Output
Circuit Topologies: Full-Bridge Type
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
500-12000W
Nature of Wave String
Sine Wave Inverter
Type
DC/AC Inverters
Model
3000W 5000W 6000W Pure Sine Wave Inverter
Built in Solar Charge Controller
Yes
Inverter Grid Type
off Grid
Wide DC Input Voltage
80-270VAC
LCD Display
Can Show Solar Generation
Selectable DC/AC Priority Function
Yes
Adjustable Charge Current
Yes
AC Output
Single or Dual Output
Frequency
High and Low Frequency
Warranty
2 Years
Transport Package
Carton or Wooden
Specification
as per model
Trademark
ZLPOWER
Origin
Shenzhen
HS Code
8504403090
Production Capacity
50, 000USD/PCS

Product Description

3000W 5000W 6000W Pure Sine Wave Inverter

 

Different Features

 

High frequency MPPT solar inverter solar hybrid inverter(Based on IGBT)

1. PSC plus 3000va 5000va pure sine wave inverter with MPPT 40A,60A solar charge controller
2. Auto restart when AC recovers


Low frequency MPPT solar inverter solar hybrid inverter(Based on Transformer)
1. GS 1-12KW pure sine wave inverter with MPPT solar charge controller, LCD can show solar and inverter parameters
2. GW Plus 1-12KW pure sine wave inverter with MPPT solar charge controller, LCD can only show inverter parameters
3. Generator restart signal
4. 3 times peak power

 

 

Same Features

1. Compatible to mains or generator power
2. AC and solar charger
3. Wide dc input votlage 80-270vac
4. Compatible to mains or generator power
5. Selectable AC or solar priority function6. Adjustable charging current





Application

ZLPOWER 3kw pure sine wave inverter can work with solar energy, generator and AC mains. They are widely used for home appliances and office devices for long time backup. 



Specifications

GS 1-12kw

MODEL
(GS Series)
HV/LV Model
HV Model(4-10KW)  LV Model(4-6KW)

Line Mode Specifications:

Input Voltage Input Voltage Waveform Sinusoidal (utility or generator)
Nominal Input Voltage LV 120Vac HV 230Vac
Low Line Disconnect Normal:85Vac±4% Wide:80Vac±4% Normal:184Vac±4% Wide:135Vac±4%
Low Line Re-connect Normal:95Vac±4% Wide:85Vac±4% Normal:194Vac±4% Wide:145Vac±4%
High Line Disconnect Normal:136Vac±4% Wide:140Vac±4% Normal:263Vac±4% Wide:263Vac±4%
High Line Re-connect Normal:131Vac±4% Wide:135Vac±4% Normal:253Vac±4% Wide:253Vac±4%
Max AC Input Voltage 150Vrms 270Vrms
Input Frequency Nominal Input Frequency 50Hz/ 60Hz (Auto detection)
Low Line Frequency Re-connect 51+0.3Hz for 60Hz;
41+0.3Hz for 50Hz;
Low Line Frequency Disconnect 50+0.3Hz for 60Hz;
40+0.3Hz for 50Hz;
High Line Frequency Re-connect 64+0.3Hz for 60Hz;
54+0.3Hz for 50Hz;
High Line Frequency Disconnect 65+0.3Hz for 60Hz;
55+0.3Hz for 50Hz;
main functions Output Voltage Waveform As same as Input Waveform
Over-Load Protection (SMPS load) Air switch
Output Short Circuit Protection Air switch
Max Bypass Overload Current 40A/50A/80A

Battery Invert Mode Specifications:

AC output Output Voltage Waveform Sine wave
Rated Output Power (KW) LV:4KW/5KW/6KW HV: 4KW/5KW/
6KW/7KW/8KW/10KW
Power Factor 0.9~1.0
Nominal Output Voltage (V) LV:120Vac ±10%rms HV:230Vac ±10%rms
Nominal Output Frequency (Hz) 60Hz ± 0.3Hz
50Hz ± 0.3Hz
DC Voltage Nominal DC Input Voltage 24VDC/48VDC
DC Voltage range 20-31.0Vdc for 24VDC
40-62.0Vdc for 48VDC
Low Battery Alarm 21.0Vdc ± 0.6Vdc for 24V battery
42.0Vdc ± 1.2Vdc for 48V battery
Low DC input Shut-down 20.0vdc± 0.6Vdc for 24V battery
40.0Vdc ± 1.2Vdc for 48V battery
High DC input Alarm & Fault 32Vdc ± 0.6Vdc for 24V battery
64Vdc ± 1.2Vdc for 48V battery
High DC input Recovery 31.0Vdc ± 0.6Vdc for 24V battery
62.0Vdc ± 1.2Vdc for 48V battery
AC Charger Nominal Charge Current 35A/50A/70A (5 stages adjustable charging current)
Charge Current Regulation ± 5Adc
Over Charge Protection Bat.V≥31.0VDC for 24V battery
Bat.V≥62.0VDC for 48V battery
beeps 0.5s every 1s & fault after 60s
Algorithm Three stage:  Boost CC (constant current stage) → Boost CV (constant voltage stage) → Float (constant voltage stage)
Solar charger Rated Charge Current 40A 60A
Rated charge battery Voltage type 24V/48V 24V
Max.PV open circuit array voltage 24V for 55Vdc
48V for 110Vdc
Charger mode MPPT
PV Low Voltage Re-connect PV≥Bat.V=3V
PV Low Voltage Disconnect PV<=Bat.V
Efficiency ≥97%
Efficiency Efficiency (Battery Mode) ≥85%
Efficiency (Line Mode) >98%
Transfer Time Ac to Dc 20ms (Max)
Dc to Ac 15ms (Max)
System parameter Over-Load Protection 110% <load<150%, beeps 0.5s every 1s, and Fault after 60s off the output, Load>150%, beeps 0.5s every 1s, and Fault after 20s.
Output Short Circuit Protection Current limit (Fault after 10s)
Surge rating (10s) 1:3 (VA)
Power saver Load <=25W (Enabled on "P/S auto" setting of Remote control)
Protections Low battery, over charging, over load , over temp.
Indicators LED+LCD Display
General Specifications Operating Temperature Range 0°C to 40°C
Storage temperature -15ºC ~60ºC
Operation humidity 5% to 95%(non-condensing)
Audible Noise 60dB max
Cooling Forced air, variable speed fan
Dimension(L*W*H) 4KW 5KW 6KW 7KW 8KW 10KW
530*400*190mm 590*420*195mm
Net weight(Kg) 30.0 35.5 38.5 41.5 48.0 55.0


GW Plus
MODEL
(GW Series)
HV/LV Model
HV Model(1-12KW)  LV Model(1-6KW)

Line Mode Specifications:

Input Voltage Input Voltage Waveform Sinusoidal (utility or generator)
Nominal Input Voltage LV 120Vac HV 230Vac
Low Line Disconnect Normal:85Vac±4% Wide:80Vac±4% Normal:184Vac±4% Wide:135Vac±4%
Low Line Re-connect Normal:95Vac±4% Wide:85Vac±4% Normal:194Vac±4% Wide:145Vac±4%
High Line Disconnect Normal:136Vac±4% Wide:140Vac±4% Normal:263Vac±4% Wide:263Vac±4%
High Line Re-connect Normal:131Vac±4% Wide:135Vac±4% Normal:253Vac±4% Wide:253Vac±4%
Max AC Input Voltage 150Vrms 270Vrms
Input Frequency Nominal Input Frequency 50Hz/ 60Hz (Auto detection)
Low Line Frequency Re-connect 51+0.3Hz for 60Hz;
41+0.3Hz for 50Hz;
Low Line Frequency Disconnect 50+0.3Hz for 60Hz;
40+0.3Hz for 50Hz;
High Line Frequency Re-connect 64+0.3Hz for 60Hz;
54+0.3Hz for 50Hz;
High Line Frequency Disconnect 65+0.3Hz for 60Hz;
55+0.3Hz for 50Hz;
main functions Output Voltage Waveform As same as Input Waveform
Over-Load Protection (SMPS load) Air switch
Output Short Circuit Protection Air switch
Max Bypass Overload Current 30A/40A/50A

Battery Invert Mode Specifications:

output Output Voltage Waveform Sine wave
Rated Output Power (KW) LV:1~6KW      HV: 1~12KW
Power Factor 0.9~1.0
Nominal Output Voltage (V) LV:120Vac ±10%rms HV:230Vac ±10%rms
Nominal Output Frequency (Hz) 60Hz ± 0.3Hz
50Hz ± 0.3Hz
DC Voltage Nominal DC Input Voltage 12VDC/24VDC/48VDC
DC Voltage range 10-15.5Vdc for 12VDC
20-31.0Vdc for 24VDC
40-62.0Vdc for 48VDC
Low Battery Alarm 10.5Vdc ± 0.3Vdc for 12V battery
21.0Vdc ± 0.6Vdc for 24V battery
42.0Vdc ± 1.2Vdc for 48V battery
Low DC input Shut-down 10.0Vdc ± 0.3Vdc for 12V battery
20.0vdc± 0.6Vdc for 24V battery
40.0Vdc ± 1.2Vdc for 48V battery
High DC input Alarm & Fault 16Vdc ± 0.3Vdc for 12V battery
32Vdc ± 0.6Vdc for 24V battery
64Vdc ± 1.2Vdc for 48V battery
High DC input Recovery 15.5Vdc ± 0.3Vdc for 12V battery
31.0Vdc ± 0.6Vdc for 24V battery
62.0Vdc ± 1.2Vdc for 48V battery
AC Charger Nominal Charge Current 20A/35A/50A/70A/90A(5 stages adjustable charging current)
Charge Current Regulation ± 5Adc
Over Charge Protection Bat.V≥15.5VDC for 12V battery
Bat.V≥31.0VDC for 24V battery
Bat.V≥62.0VDC for 48V battery
beeps 0.5s every 1s & fault after 60s
Algorithm Three stage:  Boost CC (constant current stage) → Boost CV (constant voltage stage) → Float (constant voltage stage)
Solar charger Rated Charge Current 40A 60A
Rated charge battery Voltage type 12V/24V/48V 12V/24V
Max.PV open circuit array voltage 12V for 40Vdc
 24V for 55Vdc
48V for 110Vdc
Charger mode MPPT
PV Low Voltage Re-connect PV≥Bat.V=3V
PV Low Voltage Disconnect PV<=Bat.V
Efficiency ≥97%
Efficiency Efficiency (Battery Mode) ≥85%
Efficiency (Line Mode) >98%
Transfer Time Ac to Dc 20ms (Max)
Dc to Ac 15ms (Max)
System parameter Over-Load Protection 110% <load<150%, beeps 0.5s every 1s, and Fault after 60s off the output, Load>150%, beeps 0.5s every 1s, and Fault after 20s.
Output Short Circuit Protection Current limit (Fault after 10s)
Surge rating (10s) 1:3 (VA)
Power saver Load <=25W (Enabled on "P/S auto" setting of Remote control)
Protections Low battery, over charging, over load , over temp.
Indicators LED+LCD Display
General Specifications Operating Temperature Range 0°C to 40°C
Storage temperature -15ºC ~60ºC
Operation humidity 5% to 95%(non-condensing)
Audible Noise 60dB max
Cooling Forced air, variable speed fan
Dimension(L*W*H) 3KW 5KW 6KW 8KW 10KW 12KW
     
Net weight(Kg)            



PSC Plus
Parameters            Model PSC Plus3K-24 PSC Plus5K-48
AC
Input
Nominal Power 3KVA/2400W 5KVA/4200W
Input Voltage Waveform Sinusoidal (utility or generator)
Nominal input Voltage 230VAC
Low Line  Disconnect 170Vac±4%(Normal) or 90Vac±4%(Wide & Generator) 175Vac±4%(Normal) or
125Vac±4%(Wide & Generator)
Low Line  Re-connect 180Vac±4%(Normal) or 100Vac±4%(Wide & Generator) 185Vac±4%(Normal) or 135Vac±4%(Wide & Generator)
High Line  Disconnect 280Vac±4%(Normal) or 280Vac±4%(Wide & Generator) 280Vac±4%(Normal) or 280Vac±4%(Wide & Generator)
High Line Re-connect 275Vac±4%(Normal) or 275Vac±4%(Wide & Generator) 275Vac±4%(Normal) or 275Vac±4%(Wide & Generator)
Max AC input Voltage Max:300VAC
Frequency 50Hz/60Hz(Auto detection)
AC
output
Output Voltage Waveform Sine wave
Power Factor 0.8 0.84
Nominal Output
Frequency (Hz)
50Hz / 60Hz ± 1Hz
Capable of starting electric motor 1.5HP 2.5HP
Full load efficiency ≥90%
Solar
charger
Charger  mode MPPT
Rated Charge Current 40A 60A
Max PV input Voltage 75VDC 150VDC
AC
Charger
Nominal Charger Current 20A @170Vac~280Vac; 10A @90Vac~170Vac 25A @180Vac~280Vac; 20A @125Vac~180Vac
Over charge Protection 30VDC 60VDC
Floating Charge Voltage 27.4VDC 54.8VDC
Battery
Voltage
Nominal DC input Voltage 24VDC 48VDC
Low Battery Alarm 21VDC 42VDC
High DC input Alarm & Fault 29VDC 58VDC
  Transfer Time Normal range : 10ms (typical) 15ms (max)
Generator/wide range: 20ms (typical) 40ms (max)
System
Parameter
Over-Load Protection 110%<load<150%,beeps 0.5s every 1s,and Fault after 10s off
the output,load≥150%,beeps 0.5s every 1s,and Fault after 5s
  Output Short Circuit Protection Current limit (Fault after 4 cycles max)
  Surge Rating 1:2(VA)
  Protections Low battery, over charging, over load, over temp
General
Specifications
Operating Temperature Range 0ºC to 40ºC
Storage Temperature -15ºC~60ºC
Operation Humidity 5% to 95%(non-condensing)
Audible Noise 60dB max
cooling Forced  air, variable speed fan
Dimension(L*W*H) 326*268*88.8mm 456*356.8*118mm
Net Weight(kg) 5.6kg 11.1kg
 
 

HD Plus
Parameters                  Model HD Plus1K-12 HD Plus2K-24
AC
Input
Nominal Power 1KVA/720W 2KVA/1300W
Input Voltage Waveform Nominal input Voltage
Nominal input Voltage 230VAC
Selectable Voltage Range 165-270Vac±4%(Narrow Range)                                                                                                                                                                         85-270Vac±4%(Wide Range)
Max AC input Voltage Max:270VAC
Frequency 50Hz:or 60Hz
AC
output
Output Voltage Waveform Modified sine wave
Voltage Regulation                (Bat. Mode) 230VAC (+10% / -18%)
Nominal Output
Frequency (Hz)
50Hz or 60Hz (Auto detection)
Transfer Time 15ms Typical, 20ms Max.
Solar
charger
Charger  mode PWM
Maximum PV Array Power 450W 900W
Optimal Work Voltage Rang 15VDC-18VDC 30VDC - 36VDC
MAX. PV input Voltage 55VDC
MAX. PV input Current 40Amp
AC
Charger
Charging Algorithm 3-step charging
Nominal Charger Current 15 Amp or 20Amp Selectable 10Amp
Floating Charging Voltage 13.7VDC 27.4VDC
Over charge Protection 16VDC 32VDC
Efficiency Efficiency                  (Battery Mode) >80%
Efficiency                                (Line Mode) >95%
Battery
Voltage
Nominal DC input Voltage 12VDC 24VDC
Low Battery Alarm 10.5VDC±0.3VDC 21VDC±0.6VDC
Low DC input shut-down 10VDC±0.3VDC 20VDC±0.6VDC
High DC input
Alarm & Fault
16VDC±0.3VDC 32VDC±0.6VDC
System
Parameter
Protections Low battery, over charging, over load, over temp
Indicators LCD+LED Display
Over-Load Protection 1min Load >110%,20s Load >120%,0s Load >150%
General
Specifications
Operating Temperature
Range
0ºC to 40ºC
Storage Temperature -15ºC~55ºC
cooling Forced air, variable speed fan
Dimension(L*W*H) 276.7*245*97mm
Net Weight(kg) 2.6 2.7




Photos


3000W 5000W 6000W Pure Sine Wave Inverter3000W 5000W 6000W Pure Sine Wave Inverter3000W 5000W 6000W Pure Sine Wave Inverter3000W 5000W 6000W Pure Sine Wave Inverter
3000W 5000W 6000W Pure Sine Wave Inverter




Specially Recommand: 300-12000W Solar Hybrid MPPT Inverter
3000W 5000W 6000W Pure Sine Wave Inverter




Why Choose Us

1, the company professional to do Inverter, Battery and UPS
2, the quality of ZLPOWER Products are in the top level
3, stable product quality , supply, the good faith management

Any question, please feel free to contact Sunny.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Management System Certification
ISO9001:2015, ISO14001:2015
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment