Model Parameters |
PSJ4000-48 | PSJ5000-48 | |
AC Input | Nominal Power | 4000VA/3200W | 5000VA/4000W |
Nominal input Voltage | 230VAC | ||
Selectable voltage Range | 170-280Vac(For Personal Computers) 90-280Vac(For personal Computers) |
||
Frequency | 50Hz/60Hz(Auto detection) | ||
AC Output | AC Voltage Regulation (Batt. Mode) | 230VAC ± 5% | |
Output Voltage Waveform | Pure sine wave | ||
Surge Power | 8000VA | 10000VA | |
Transfer Time | 10 ms (For Personal Computers); 20 ms (For Home Appliances) | ||
Full load efficiency | 93% | ||
Solar Charger & Ac Charger | Maximum PV Array Open Circuit Voltage | 105VDC | |
Maximum Solar Charge Current | 50A | ||
Maximum AC Charge Current | 60 A | ||
Maximum Charge Current | 110A | ||
Standby Power Consumption | 2 W | ||
Battery | Battery Voltage | 48 VDC | |
Floating Charge Voltage | 54 VDC | ||
Overcharge Protection | 60 VDC | ||
General Specifications |
Operating Temperature Range | 0ºC to 55ºC | |
Storage Temperature | -15ºC~60ºC | ||
Operation Humidity | 5% to 95% Relative Humidity(Non-condensing) | ||
Dimension(L*W*H) | 120*295*468mm | ||
Net Weight(kg) | 9.8kg |