Model: UPS Uninterrupted Power Supply, pure sine wave UPS 20k-40k
1: Three phase input and three phase output
2: Industry use
3: Large overload capacity
4. CE
Key features:
1. N+X parallel redundancy (compatible to battery share in the parallel mode) The maximum of the inbuilt parallel mode is 8 UPS without any other external accessories, which helps the customer to extend the system capacity with low cost.
2. Intelligent management of battery charging and discharging
3. Frontal-board operation and maintenance
4. Twin-channel line input. The UPS provides customer security in power supply with intelligent choice between two-line input or one-line input according to the actual condition.
5. Remote monitoring. Communication interfaces like RS232/RS485, Intelligent Slot are available for the realization of remote management and monitoring. In addition, the optional AS400 card is suitable for the connection of stem point, which enriches the customer's choice out of the monitoring demand
6. UPS with High-efficient DSP chip
7. Excellent performance in industrial environment protection. Just with the standard product, IP21 protection level protecting the machine from the intrusion of solid material with the diameter larger than 12mm or the water drops) is achieved.
Application: Metro, Oil field, Army, Banks, Telecommunication, Power Plants and so on.
three phase ups |
HP33 10-80KVA |
Model |
HP3310K |
HP3315K |
HP3320K |
HP3330K |
HP3340K |
HP3360K |
HP3380K |
Capacity (VA/W) |
10KVA/8KW |
15KVA/12KW |
20KVA/16KW |
30KVA/24KW |
40KVA/32KW |
60KVA/48KW |
80KVA/64KW |
Rectifier Input |
RectifierType |
IGBT-based Vector Controlled PFC(PF Corrected) |
|
Input Voltage |
380/400/415VAC(Accepted from 305 to 477 without battery use) |
|
Input Frequency |
50Hz or60HZ(Accepted range from 40 to 70) |
|
Input Power Factor |
≥0.99(without any Filter) |
Bypass Input |
Input Voltage |
380/400/415VAC |
Battery |
BatteryType |
VRLA(Valve Regulated Lead Acid) or Wet/Flooded or NiCd |
End-Cell Voltage |
1.60-1.90VDC(for VRLA) |
Output |
Inverter Type |
IGBT-based Vector,Repetitive&PI Controlled |
Output Voltage |
380/400/415VAC±5 Regulation(3-phase RMS average) |
Output Frequency |
50/60HZ(±0.05) |
Max.Leading PF Load |
Up to 0.9 |
Overload |
110% for 60 minutes,125% for 10 minutes,150% for 1 minute, |
Main unit |
Dimension(W×D×H)mm |
420×643×956 |
420×643×956 |
420×643×956 |
470×710×1150 |
470×710×1150 |
673×835×1550 |
673×835×1550 |
Wight(KG) |
115 |
117 |
122 |
160 |
164 |
450 |
510 |
Any more information about us ,pls let ,me know