MPPT solar charger controller 12V/24V 40Amp and 60Amp, Optional LCD digital display, PWM technology, parallel output function.
Application:
SL-40A/60A solar charge controller is mainly used for solar power station, home solar power system, solar street light control system, mobile solar power system, DC wind solar generating systems.
Main Features:
Adopt advanced MCU microprocessor control technology.
12V/24V self detect to choose output voltage.
Advanced MPPT Technology, High converting efficiency higher than 97% for minimizing energy loss.
Capable to parallel in output, to expand capacity easily.
Reversed current protection at night, over voltage and reverse polarity protection.
Capable of selecting different charging mode for various types of batteries
Capable of connecting additional DC load for wider applications
Three stage charge control system (bulk, absorption, and float mode) with optional temperature compensation
LED indicators display charge status in real time, Optional LCD digital display.
Pulse Width Modulation (PWM) technology combined with a multi-stage charge control algorithm leads to superior charging and enhanced battery performance.
MPPT solar charger controller |
SL-40A/60A |
Rated Voltage |
12/24Vdc auto-detection |
Rated charge current (include load current) |
40Amp/60Amp |
Load current |
15Amp |
Input voltage range |
15-55Vdc |
Max. PV open circuit array voltage |
55Vdc |
Overload protection (DC load) |
2.0 * Inom>5s |
1.5 * Inom >20s |
1.25 * Inom temperature controlled |
Typical idle consumption |
At idle < 10mA |
Bulk charge |
14.6Vdc (default) |
29.2Vdc (default) |
Floating charge |
13.4Vdc (default) |
26.8Vdc (default) |
Equalization charge |
14.0Vdc (default) |
28.0Vdc (default) |
Over charge disconnection |
14.8Vdc |
29.6Vdc |
Over charge recovery |
14Vdc |
28Vdc |
Over discharge disconnection |
10.8Vdc (default) |
21.6Vdc (default) |
Over discharge reconnection |
12.3Vdc |
24.6Vdc |
Temperature compensation |
-13.2mV/centi-degree |
-26.4mV/centi-degree |
Lead acid battery settings |
Adjustable |
NiCad battery settings |
Adjustable |
Load control mode |
1. Low Voltage Reconnect (LVR): Automatic |
2. Low Voltage Disconnect (LVD): Automatic |
3. Reconnection: warning flash before disconnect and reconnection |
Low voltage reconnect |
12.0-14.0Vdc |
24.0-28.0Vdc |
Low voltage disconnect |
10.5-12.5Vdc |
21.0-25.0Vdc |
Ambient temperature |
0-40centi-degree(full load) 40-60centi-degree(de-rating) |
Altitude |
Operating 5000 m, Non-Operating 16000 m |
Protection class |
IP21 |
Cooling |
natural cooling |
Terminal size (fine/single wire) |
#8 AWG |
Dimension(L*W*H) |
192*140*66mm |
Any more requirements ,pls feel free to contact Bella