• Long Time Backup UPS Power Supply 1kVA 2kVA 3kVA 6kVA 10kVA Outdoor Online UPS
  • Long Time Backup UPS Power Supply 1kVA 2kVA 3kVA 6kVA 10kVA Outdoor Online UPS
  • Long Time Backup UPS Power Supply 1kVA 2kVA 3kVA 6kVA 10kVA Outdoor Online UPS
  • Long Time Backup UPS Power Supply 1kVA 2kVA 3kVA 6kVA 10kVA Outdoor Online UPS
  • Long Time Backup UPS Power Supply 1kVA 2kVA 3kVA 6kVA 10kVA Outdoor Online UPS
  • Long Time Backup UPS Power Supply 1kVA 2kVA 3kVA 6kVA 10kVA Outdoor Online UPS

Long Time Backup UPS Power Supply 1kVA 2kVA 3kVA 6kVA 10kVA Outdoor Online UPS

Phase: Single Phase
Type: Outdoor Online UPS
Protection: Short Circuit
Application: Spaceflight
Classification: Lighting/Power
Standby Time: Standard Machine
Samples:
US$ 680/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

Contact Supplier

Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
RA1K-10K
Standby UPS
Sine Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Centralized Model
Brand
Zlpower
Frequency Precision
50/60Hz±0.05Hz
Power Factor
0.7/0.8(Optional) Standard 0.7
Crest Factor
3:1
Communicate Interface
RS232
Design
Cold Start Function
Battery Type
Lead-Acid Maintenance-Free Battery
Name
Pure Sine Wave Power Supply Outdoor UPS 1kVA to 1
Warranty
2 Years
Cooling
Air Conditions, Fans
Working Tem
-40 to + 65 Degree
Monitor
Snmp Card
Wave
Pure Sine Wave
Suitable Environment
Any Harsh Environment
Certificates
CE, FCC
Service-Life Design
20 Years
Transport Package
Wooden Package
Specification
85KG-155KG
Trademark
zlpower/OEM
Origin
China
HS Code
8504402000
Production Capacity
10000PCS/Month

Product Description

Long Time Backup UPS Power Supply 1KVA 2KVA 3KVA 6KVA 10KVA Outdoor Online UPS

Key features
1.ZLPOWER Outdoor Intelligent High Frequency Online UPS provide continuous pure sine wave AC power supply for
outside communications / network equipment.

2.Double-conversion online design, high temperature resistant, anti-cold, sealing level for IP65; With the wide range of input voltage and frequency of input window (- 45% +35% rated voltage and ± 10% rated frequency), in many remote areas of China after a severe test of the grid.

3.Using microprocessor control, directly produce highfrequency pulse width modulation wave (SPWM) control of the UPS inverter, to simplify the UPS control circuit, to improve the stability, to have more real-time UPS to quickly respond to changes in the external environment and guarantee the machine's control circuit is more simple and reliable.

4.Using digital control techniques, to avoid the traditional analog control temperature drift inherent defects such as
hardware parameters, to ensure consistency and reliability of UPS.


Specification
Model RA1KL RA2KL RA3KL RA6KL RA10KL
Capacity VA/W 1000VA/800W 2000VA/1600W 3000VA/2400W 6000VA/4800W 10000VA/8000W
Input Nominal Voltage 200/208/220/230/240VAC
Voltage Range 115~300VAC 125~275VAC
Power Factor 0.97
Frequency Range 50Hz:46~54Hz; 60Hz:56~64Hz
Output Voltage 200/208/220/230/240(1±2%)VAC 200/208/220/230/240(1±1%)VAC
Frequency 50/60Hz (Adjustable);
50Hz AC Mode: Follow AC Mode (AC Range 46~54Hz); Battery Mode: 50Hz (1±0.2%)                                                                                                 60Hz AC Mode: Follow AC Mode (AC Range 56~64Hz); Battery Mode: 60Hz (1±0.2%)
Wave Form Pure sine wave
Power Factor 0.8
Harmonic Distortion 3% THD (Linear load)
7% THD (Non-Linear load)
2% THD (Linear load)
6% THD (Non-Linear load)
Overload Capacity 110%~150%  maintain 30s then turn to bypass ourput;
>150% maintain 300ms
Load <105% work consistant;
105%
<load <125% 1min;
125%
<load <135% 30sec;>135% 0.5sec
Current Crest Ratio 3:01
Connections Terminal block
Efficiency Battery Mode 83% 87%
AC Mode 85% 88%
Battery Type Sealed free maintenance lead acid battery
Nominal DC voltage 36VDC 96VDC 96VDC 192VDC 192VDC
Stansard Battery Cabinet 3*100AH 8*100AH 8*100AH 16*38AH 16*38AH
Backup Time (Full Load) Depens on the capacity of internal battery bank(24AH,38AH,65AH,80AH and 100AH optional) Depens on the capacity of internal battery bank(24AH,38AH optional)
Charge Current (Max) 6.0A 6.0A 6.0A 2.0A 2.0A
Charge Voltage (VDC) 41.1V±0.2VDC 110V±0.6VDC 110V±0.6VDC 219.5V±1.1%VDC 219.5V±1.1%VDC
Recharge Time Depends on the capacity of  internal battery bank
Bypass Automatic Transfer On overload and UPS failure
Before UPS Power-on YES
Transfer Time   0 ms(from imain to battery and vice versa); Less than 4ms from inverter to bypass and vice versa
indicators LCD Display UPS status, Battery capacity, loading, Fault code (LCD: I/P &O/P voltage&frequency, Battery voltage)
Audible   Bypass, Battery mode, Battery low, Overload, Fault
Communications Intelligent RS232 serial port Software support Windows family software, Linux, Sun network operating system, IBM Aix, Compaq True64 SGI IRIX, FreeBSD, HP-UX and MAC 
SNMP (Optional) Remote control UPS through SNMP management and Internet
USB (Optional) Windows family software and Mac OS
Environmental Operating Temperature 0~40ºC
Operating Humidity 0~95% (No condensing)
UPS dimension L*W*H (mm)(UPS main body) 482*380*88.4 482*448*88.4 482*448*88.4 632*482*133.4 632*482*133.4
L*W*H (mm)(Cabinet) 638*507*775 612*525*1511 612*525*1511 718*595*1371 718*595*1371
Weight(kg) Net Weight (No battery) 52.00 100.00 100.00 120.00 123.00


Photos
Long Time Backup UPS Power Supply 1kVA 2kVA 3kVA 6kVA 10kVA Outdoor Online UPSLong Time Backup UPS Power Supply 1kVA 2kVA 3kVA 6kVA 10kVA Outdoor Online UPSLong Time Backup UPS Power Supply 1kVA 2kVA 3kVA 6kVA 10kVA Outdoor Online UPSLong Time Backup UPS Power Supply 1kVA 2kVA 3kVA 6kVA 10kVA Outdoor Online UPS

Package
Long Time Backup UPS Power Supply 1kVA 2kVA 3kVA 6kVA 10kVA Outdoor Online UPS
COMPANY SHOW:
Long Time Backup UPS Power Supply 1kVA 2kVA 3kVA 6kVA 10kVA Outdoor Online UPSLong Time Backup UPS Power Supply 1kVA 2kVA 3kVA 6kVA 10kVA Outdoor Online UPS
FAQ:

Q 1. What's the payment terms and payment method ? 
A. We accept L/C, T/T, Credit Card, Western Union, Money Gram, etc.

Usually 30% deposit, 70% before shipment.

Q 2. How's the delivery time ?
A.  It  usually takes about 3-10 days after payment arrived.

Q 3. How about package ?
A. For the small UPS and the inverters less than 30kg will be packed in foams and cartons. For the big UPS and inverters heavier than 30kg will be packed in pallets or wood boxes .


Q 4. Would you accept to print our logo and design ?
A. Yes, we can print your logo on the inverters, UPS and cartons. Also welcomed your own design of these inverters and UPS.

Q 5. What kind of certificates you have ?
A. For company have ISO9001, ISO14001, TUV and SGS factory certification.

For UPS and power inverters, we have CE,IEC, KC and ETL, etc.

Q6. When the product have problem, how to solve it ?
A. We have a professional after-sales team, in case of any problems, first contact us to help you solve, we have a 24 months warranty and lifetime technical support. We will track product usage until you are satisfied.

Send your message to this supplier

*From:
*To:
avatar Mrs. Phylis Song
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Contact Supplier

Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Management System Certification
ISO9001:2015, ISO14001:2015
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment