Customization: | Available |
---|---|
Nature of Source Flow: | Passive inverter |
Certification: | ISO9001, CE |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Default Battery System Voltage | 24VDC | 48VDC | 24VDC | 48VDC | 24VDC | 48VDC | 48VDC | 48VDC | 48VDC | |
INVERTER OUTPUT | Continuous output power | 5KVA/4.0KW | 6KVA/4.8KW | 7.5KVA/6.0KW | 10KVA/8.0KW | 12.5KVA/10.0KW | 15KVA/12.0KW | |||
Surge rating (20ms) | 12.0KW | 15.0KW | 18.0KW | 24.0KW | 30.0KW | 36.0KW | ||||
Capable Of Starting Electric Motor | 2HP | 3HP | 3HP | 4HP | 5HP | 6HP | ||||
Output waveform | Pure sine wave/ same as input (bypass mode) | |||||||||
Inverter Efficiency(Peak) | >88% | |||||||||
Line mode efficiency | >95% | |||||||||
Power factor | 1.0 | |||||||||
Nominal output voltage RMS | 220V/230V/240VAC(+/-10% RMS) | |||||||||
Output frequency | 5OHz/60Hz +/-0.3 Hz | |||||||||
Short circuit protection | Yes (1sec after fault) | |||||||||
Typical transfer time | 10ms(max) 10ms(max) | |||||||||
AC INPUT | Voltage | 230VAC | ||||||||
Selectable Voltage Range | 155~280VAC(For Personal Computers) | |||||||||
Frequency Range | 50HZ/60HZ (Auto sensing) 40~80Hz | |||||||||
BATTERY | Minimum start voltage | 20.OVDC/21.0VDC for24VDC mode (40.OVDC/42.0VDC for 48VDC mode) | ||||||||
Low battery alarm | 21.0VDC+/-0.3V for 24VDC mode (42.OVDC+/-0.6V for 48VDC mode) | |||||||||
Low battery Cutoff | 20.0VDC+/-0.3V for 24VDC mode (40.OVDC+/-0.6V for 48VDC mode) | |||||||||
High voltage alarm | 32.0VDC+/-0.3V for 24VDC mode (64.OVDC+/-0.6V for 48VDC mode) | |||||||||
High battery voltage recover | 31.0VDC+/-0.3V for 24VDC mode (62.OVDC+/-0.6V for 48VDC mode) | |||||||||
Idle consumption-search mode | <25W when power saver on | |||||||||
CHARGER | Output voltage | Depends on battery type | ||||||||
Charger AC input breaker rating | 30A | 30A | 30A | 40A | 50A | 63A | ||||
Max charge power rate | 1/3 Rating power | |||||||||
Overcharge protection S.D. | 31.4VDC for 24VDC mode (62.8VDC for 48VDC mode ) | |||||||||
Maximum Charge Current | 65A | 35A | 65A | 40A | 65A | 50A | 70A | 80A | 100A | |
BTS | Continuous output power | Yes Variances in charging voltage & S.D. voltage base on the battery temperature | ||||||||
BYPASS & PROTECTION | Input voltage waveform | Sine wave (grid or generator) | ||||||||
Nominal voltage | 220V/230V/240VAC | |||||||||
Max input AC voltage | 300VAC for 230VAC HV mode | |||||||||
Nominal input frequency | 50Hz or 60Hz | |||||||||
Overload protection (SMPS load) | Circuit breaker | |||||||||
Output short circuit protection | Circuit breaker | |||||||||
Bypass breaker rating | 40A | 40A | 40A | 50A | 63A | 63A | ||||
Max bypass current | 40Amp | 80Amp | ||||||||
Rated voltage | 24VDC/48VDC | |||||||||
PV open circuit voltage | Operational max = 145VDC temperature corrected VOC | |||||||||
SOLAR CHARGER | Maximum PV Charge Current | 60A | 60A(120A Optional) | |||||||
DC Voltage | 24V/48V atuo work | 48V | ||||||||
Maximum PV Array Power | 1600W | 3200W | 1600W | 3200W | 1600W | 3200W | 3200W(6400W for 120A Optional) | |||
MPPT Range @ Operating Voltage | 32-145VDC for 24V mode,64-145V for 48V mode | 64~145VDC | ||||||||
Maximum PV Array Open Circuit Voltage | 147VDC | 147VDC | ||||||||
Maximum Efficiency | >98% | |||||||||
Standby Power Consumption | <2W | |||||||||
MECHANICAL SPECIFICATIONS | Mounting | Wall mount | ||||||||
Inverter dimensions (W*H*D) | 517*414*211mm | 587*414*211mm | ||||||||
Inverter weight (solar chg) KG | 38+2.5 | 48+2.5 | 49+2.5 | 60+2.5 | 66+2.5 | 70+2.5 | ||||
Shipping dimensions(W*H*D) | 650*520*310mm | 750*520*310mm | ||||||||
Shipping weight (solar chg) KG | 40+2.5 | 50+2.5 | 51+2.5 | 62+2.5 | 68+2.5 | 72+2.5 | ||||
OTHER | Operation Temperature Range | 0°C to 40°C | ||||||||
Storage Temperature | -15°C to 60°C | |||||||||
Audible Noise | 60dB MAX | |||||||||
Display | LED+LCD | |||||||||
Standard warranty | 1 year |