Model: Rack Mount UPS, Rack UPS, 1kVA-6kVA for server
1. High Frequency UPS 1kVA~6kVA
2. Zero transfer
3. SNMP monitor software
4. CE
Key feature:
High frequency UPS with GIBT technology
Module design UPS
Overload and short circuit protection
LED statue display( LCD display)
Intelligent slot for SNMP adaptor(optional)
Cold start
Bypass protection
APPLICATION
Servers, Data-Center, Critical network devices, Sensitive electronic equipment, Telecom, etc
Rack Mount UPS Model |
RM1KE |
RM2KE |
RM3KE |
RM1KE-L |
RM2KE-L |
RM3KE-L |
RM6KE-L |
RM10KE-L |
Rated Power |
VA/W |
1kVA/0.7kW |
2kVA/1.4kW |
3kVA/2.1kW |
1kVA/0.7kW |
2kVA/1.4kW |
3kVA/2.1kW |
6kVA/4.8kW |
10Kva/8Kw |
Input |
Phase |
Single Phase with Ground |
Nominal Voltage |
110/115/120Vac or 220/230/240Vac |
220/230/240Vac |
Voltage Range |
60-138VAC or 115 ~ 300VAC |
176 ~ 276VAC |
Frequency Range |
46 ~ 54Hz(default), user adjustable within 40~60Hz |
46 ~ 54Hz |
Power Factor |
0.97 |
0.98 |
Connection |
IEC320-10A inlet |
IEC320-16A inlet |
IEC320-10A inlet |
IEC320-16A inlet |
Terminal Block |
Output |
Phase |
Single Phase |
Voltage |
110/115/120Vac or 220/230/240VAC ± 2% |
110/115/120Vac or 220/230/240VAC± 1% |
Frequency |
46~54Hz or 50Hz ± 0.2Hz (Line mode) |
46~54Hz (Line mode) |
50Hz ± 0.2Hz ( Battery mode) |
50Hz ± 0.05Hz ( Battery mode) |
Waveform |
Pure Sine Wave |
Overload Capability |
108%~150% for 30 sec., 150% for 300 ms |
105%~130% for 10 min.,130% for 1 min. |
Current Crest Ratio |
3:1 |
Connections |
IEC320 -10A * 4 |
IEC320 -10A * 4 |
IEC320-10A and Terminal Block |
IEC320 -10A * 4 |
IEC320 -10A * 4 |
IEC320-10A and Terminal Block |
IEC320-10A * 4 and Terminal Block |
Bypass |
Automatic Transfer |
on overload and UPS failure |
Before UPS Power-on |
Default "NO", user adjustable to "YES" |
Yes |
Voltage Range |
80~264VAC (Default), user adjustable within 80~286VAC |
176 ~ 261VAC |
Transfer Time |
0 ms; less than 4 ms from inverter to bypass and vice versa |
Zero |
LED indicators |
Load level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault |
Audible Alarm |
Bypass, On battery mode, Battery low, Overload, Fault |
Communications |
RS-232 Serial Interface |
Intelligent Slot; |
OPTIONS: WEBPOWER SNMP/WEB card, AS400 card or WinPower CMC) |
Network Surge Protection |
RJ45 I/O port available for network or Fax/Modem |
Environmental |
Operating Temperature |
0 ~ 40centi-degree |
Operating Humidity |
20 ~ 90% non-condensing |
Main Unit |
Net Weight (Kg) |
16.3 |
10.3 |
11.2 |
9.1 |
11.5 |
12.3 |
18.3 |
20.3 |
Dimensions (L x W x H) mm |
482 x 420 x 88 (2U) |
600 x 482.6 x 130 (3U) |
Battery Pack |
Type |
Internal Batteries |
External Battery Pack |
Nominal DC Voltage |
36VDC |
96VDC |
36VDC |
96VDC |
192VDC |
Battery Numbers & Capacity |
3Pcs *12V7.2Ah |
8Pcs *12V7.2Ah |
8Pcs *12V7.2Ah |
Depending on the capacity of external battery packs |
Backup Time (Full load) |
5 min |
9 min (with 1 BP) |
5 min (with 1 BP) |
Recharge Time |
5hrs to 90% |
5hrs to 90% |
5hrs to 90% |
Charging Current (Max.) |
1.0A |
1.0A |
1.0A |
8A±1A |
4.2A |
Charging Voltage |
41.1Vdc±0.6V |
110Vdc±0.4V |
41.1Vdc±0.6V |
110Vdc±0.4V |
216Vdc±1%V |
Net Weight (Kg) |
--- |
25.3 |
25.3 |
--- |
--- |
--- |
--- |
Dimensions (L x W x H) mm |
--- |
482 x 420 x88 (2U) |
482 x 420 x88 (2U) |
--- |
--- |
--- |
--- |
Any more requirements for us,pls do not hesitant to contact Bella