Customization: | Available |
---|---|
Condition: | New |
Application: | Solar System |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MPPT solar charger controller |
SL-40A/60A | |
Rated Voltage | 12/24/48Vdc auto-detection | |
Rated charge current (include load current) | 40Amp/60Amp | |
Load current | 15Amp | |
Input voltage range | 15-55Vdc | |
Max. PV open circuit array voltage | 55Vdc | |
Overload protection (DC load) | 2.0 * Inom>5s | |
1.5 * Inom >20s | ||
1.25 * Inom temperature controlled | ||
Typical idle consumption | At idle < 10mA | |
Bulk charge | 14.6Vdc (default) | 29.2Vdc (default) |
Floating charge | 13.4Vdc (default) | 26.8Vdc (default) |
Equalization charge | 14.0Vdc (default) | 28.0Vdc (default) |
Over charge disconnection | 14.8Vdc | 29.6Vdc |
Over charge recovery | 14Vdc | 28Vdc |
Over discharge disconnection | 10.8Vdc (default) | 21.6Vdc (default) |
Over discharge reconnection | 12.3Vdc | 24.6Vdc |
Temperature compensation | -13.2mV/°C | -26.4mV/°C |
Lead acid battery settings | Adjustable | |
NiCad battery settings | Adjustable | |
Load control mode | 1. Low Voltage Reconnect (LVR): Automatic | |
2. Low Voltage Disconnect (LVD): Automatic | ||
3. Reconnection: warning flash before disconnect and reconnection | ||
Low voltage reconnect | 12.0-14.0Vdc | 24.0-28.0Vdc |
Low voltage disconnect | 10.5-12.5Vdc | 21.0-25.0Vdc |
Ambient temperature | 0-40°C (full load) 40-60°C (de-rating) | |
Altitude | Operating 5000 m, Non-Operating 16000 m | |
Protection class | IP21 | |
Cooling | natural cooling | |
Terminal size (fine/single wire) | #8 AWG | |
Dimension(L*W*H) | 192*140*66mm |