LED Model | LW500 | LW750 | LW1000 | LW1500 | LW2000 | LW2500 | LW3000 | LW4000 | LW5000 | LW6000 | LW7000 | |
LCD Model | / | / | LW1000-C | LW1500-C | LW2000-C | LW2500-C | LW3000-C | LW4000-C | LW5000-C | LW6000-C | LW7000-C | |
Nominal Power | 500W | 750W | 1000W | 1500W | 2000W | 2500W | 3000W | 4000W | 5000W | 6000W | 7000W | |
AC Input | Phase & waveform | Single Phase & Pure Sine Wave | ||||||||||
Norminal Voltage | 120VAC/230VAC OR 220/230/240VAC | |||||||||||
Acceptable Voltage | 95-126VAC OR 194-253VAC±4% | |||||||||||
Line Low Disconnect | 85V±4% OR 184±4% (154 wide mode±4%) | |||||||||||
Line Low Reconnect | 95V±4% OR 194 ±4%(164 wide mode±4%) | |||||||||||
Line High Disconnect | 136V±4%/274±4% | |||||||||||
Line High Reconnect | 126V±4%/264±4% | |||||||||||
Frequency | 50Hz(41-54) or 60Hz(51-64) (auto sensing) | |||||||||||
AC Output | Phase & Waveform | Single Phase & Pure Sine Wave (bypass mode sync to input) | ||||||||||
Voltage | 110/120/130VAC OR 220/230/240VAC±10%rms (bypass mode sync to input) | |||||||||||
Voltage Regulation | ±10%rms (bypass mode sync to input) | |||||||||||
Frequency | 50Hz±0.3Hz OR 60Hz±0.3Hz (bypass mode sync to input) | |||||||||||
Peak Power | 3 times of rating power | |||||||||||
Short Circuit Protection | Yes, shutdown after 10ms | |||||||||||
Power Factor | 0.9-1.0 | |||||||||||
DC Input | Battery Voltage | 12/24V dc | 12/24/48Vdc | 24/48Vdc | 48 | |||||||
Minimum Start Voltage | 10V for 12V, 20V for 24V, 40V for 48V | |||||||||||
Low Battery Alarm | 10.5±0.3Vdc for 12V, 21±0.6Vdc for 24V, 42V±1.2for 48V | |||||||||||
Low Battery Transfer | 10V±0.3Vdc for 12Vdc, 20V ±0.6Vdcfor 24V, 40V ±1.2Vdcfor 48V | |||||||||||
High Voltage Alarm | 16V±0.3 for 12V, 32V ±0.6for 24V, 64±1.2V for 48V | |||||||||||
High DC Input Recovery | 15.5±0.3Vdc or 31±0.6Vdc or 62V±1.2Vdc | |||||||||||
Max Charge Current | 15A20A/35A/50A/75A(According to the inverter model) | |||||||||||
Transfer Efficiency | Line Mode | >96% | ||||||||||
Battery Mode | >85% | |||||||||||
System Parameter | Power Saver | Load<=25W(Enabled on "P/S auto"setting of Remote Control | ||||||||||
Audible Alarm | Souding when the heat sink 's temperature is over 100ºCand shut down after 30 seconds | |||||||||||
Over Load Protection | 110%<Load<150%,beep 0.5s every 1s,and fault after 60s | |||||||||||
Load>150%,beeps 0.5s every 1s,and fault after 20s | ||||||||||||
Protections | low battery,over charging,over temp,over load | |||||||||||
Communications | RS-232/USB/SNMP(custom-made) | |||||||||||
Operating Environment | 0-40ºC,0-90%RH(non-condensing) | |||||||||||
Audible Noise | <60dB | |||||||||||
Net Weight(KG) | 8.5 | 8.5 | 14 | 18.5 | 18.5 | 23.6 | 23.6 | 34 | 37.5 | 46.5 | 46.5 | |
Dimension L X W X H(mm) |
380*182*160mm | 470×223×185mm | 650×223×185mm |