| Customization: | Available |
|---|---|
| After-sales Service: | Yes |
| Warranty: | 24months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Model No. | LW1000 | LW2000 | LW3000 | LW4000 | LW5000 | LW6000 |
| Nominal Power | 1000W | 2000W | 3000W | 4000W | 5000W | 6000W |
| AC Input | ||||||
| Phase & waveform | Single phase & Pure Sine Wave | |||||
| Voltage | 120VAC/230VAC | |||||
| Acceptable Voltage | 194-243VAC\164-243VAC(wide mode ) | |||||
| Line Low Transfer | 85V±4%/184(154 wide mode±4%) | |||||
| Line Low Return | 95V±4%/194(164 wide mode±4%) | |||||
| Line high Transfer | 135V±4%/253±4% | |||||
| Line high Return | 127V±4%/243±4% | |||||
| Frequency | 50Hz or 60Hz (auto sensing) | |||||
| Line Low Transfer | 47Hz for 50Hz,57Hz for 60Hz | |||||
| Line high Transfer | 55Hz for 50Hz,65Hz for 60Hz | |||||
| Output | ||||||
| Phase & waveform | Single phase & Pure Sine Wave ( bypass mode sync to input ) | |||||
| Voltage | 120/220/230/240VAC ( bypass mode sync to input ) | |||||
| Voltage Regulation | ±10%rms ( bypass mode sync to input ) | |||||
| Frequency | 50Hz±0.3Hz ( bypass mode sync to input ) | |||||
| Peak Power | 3 times of rating power | |||||
| Short Circuit Protection | Yes,shutdown after 10ms | |||||
| Power Factor | 0.9-1.0 | |||||
| DC Input | ||||||
| Battery Voltage | 12V/24V | 12V/24V/48V | 24V/48V | |||
| Minimum Start Voltage | 10V for 12V,20V for 24V,40V for 48V | |||||
| Low Battery Alarm | 10.5V for 12V,21V for 24V,42V for 48V | |||||
| Low Battery Transfer | 10V for 12V,20V for 24V,40V for 48V | |||||
| High Voltage Alarm | 16V for 12V,32V for 24V,64V for 48V | |||||
| Max Charging Current | 35A/70A | |||||
| Over Charge Voltage | 15.7V for 12V,31.4V for 24V,62.8V for 48V | |||||
| Transfer Efficiency | ||||||
| Line Mode | > 95% | |||||
| Battery Mode | > 88% | |||||
| power saver | Available when the load is less than 25 Watts | |||||
| Indicators | ||||||
| 7-LED Display | From the right to the left,LED1 line mode (green lighting) , LED2 inverter mode | |||||
| (green lighting) , LED3 charging mode ( yellow lighting ), LED4 Fully charged | ||||||
| (green lighting) , LED5 over heat shutdown(red lighting ), LED6 Overloaded | ||||||
| shutdown ( red lighting ), LED7 Saving Mode ( green lighting ) | ||||||
| 3-LED Display | Charging Mode(green lighting) , inverter mode(green lighting) , Alarm ( red lighting ) | |||||
| Switch selector | Saving Mode is on/off when push the switch forwards/backwards, keeping it horisontal is | |||||
| turning the inverter off. | ||||||
| Audible Alarm | Sounding when the heatsink's tem is over 105 °C and shutdown after 30 seconds. | |||||
| Protections | low battery , over charging , over temp , over load | |||||
| Communications | RS-232/USB(custom-made ) | |||||
| Enviromental | ||||||
| Operating Environment | 0-40 °C ,0-90%RH(non-condensing) | |||||
| Audible Noise | < 60dB | |||||