3 Phase UPS - 3 Phase UPS System 10K-400KVA for Industry, Telecom, School and Hospital use
1: UPS System Input power factor >0.98
2: Can connect 6 Units UPS in Parallel
3: Ture Online UPS with double onversion
4: UPS with IGBT, PWM inverter together with digital
3 Phase UPS Key features
1) Rated at 0.9 output power factor, more applicable to server
Computer and network center that use PFC technology in a large scale, and deliver more Active power than
Conventional UPS
2) Advanced distributed active parallel technology can realize parallel operation of 6 UPS
Units without the need of centralized bypass cabinet
3) 6-inch extra large LCD that display 12 language( Chinese. English. Russian. Spanish. French^)
4) The efficiency of the machine is more than 94%, and reach 98% in ECO mode.
5) Use advanced 6th generation DSP and full digital control technologies to realize higher
System stability
6) Intelligent battery management maintains battery automatically to prolong the battery life
7) Standard input/output filter improves the system EMC performance
8) Layered independently-sealed ventilation channel and redundant fan, circuit boardswith protective paints and a dust filter embedded make it highly efficient to dissipate heat and protect the product effectively under severe environment
UPS Ssytem Application:
1: Data management equipment and system
2: Automatic control systems
3: Hospital
4: Mini office system
5: Telecommunication systems
6: Bank
7: Industry
8: Labs
9: Alarm System
10: Building, Off-board etc
Payment Details:
Payment Terms: Negotiation
Minimum Order: 1Unit
Delivery Details:
FOB Port: Shenzhen
Lead Time: 5 - 25 days
Product Certifications: CE Certificate
Model |
GP3310 ~ GP33200 series Low Frequency Online UPS |
Capacity (VA) |
10K |
15K |
20K |
30K |
40K |
60K |
80K |
100K |
120K |
160K |
200K |
Noninal output capacity |
8KW |
12KW |
16KW |
24KW |
32KW |
48KW |
64KW |
80KW |
96KW |
128KW |
160KW |
Operate type |
Double conversion low frequency online type |
Input |
voltage |
220V/380, 230/400, 240/415V, ±25% |
Phase |
Three phase +N+G |
Frequency |
50Hz/60Hz±5% |
Input power factor |
0.95(with input filter) |
Soft start |
0-100% 5sec |
Output |
Voltage |
220V/380, 230/400, 240/415V, ±1% (stable load), ±5%(active load) |
Phase |
Three phase +N+G |
Frequency |
50/60Hz (1±5%, AC mode), 50/60Hz (±1%, Battery mode) |
Power factor |
0.8 |
Output wave |
Pure sine wave |
Distortion |
Linear load <3%, non linear load<5% |
Battery voltage |
Standard battery voltage |
360V/384V |
Floating charge |
405V/432V |
Terminal voltage |
315V/336V |
Charge current |
1A-50A (Can calculate and set according to battery configuration software) |
Maximum discharge current |
28 |
42 |
56 |
85 |
113 |
169 |
225 |
282 |
338 |
381 |
507 |
Main Function |
Active voltage change |
0-100%±5% |
Instant recover time |
<10ms |
Imbalance voltage |
<±5%,<±1%( Balance load voltage) |
Overload capacity |
125%→10min,150%→1min |
Static switch |
Automatic |
Protection |
UPS over current, short circuit, battery low voltage, over heat |
Cold method |
Compel aeration ( temperature control mode) |
Noise |
60-65dB |
Display |
LED\LCD display |
Communication port(Optional) |
RS232, SNMP, dry-contact |
Alarm |
Alarm with buzzer and indicators |
Environment |
Temperature: 0-40C Humidity: 0-90% |
Net weight |
kgs |
210 |
258 |
350 |
400 |
480 |
900 |
1100 |
1200 |
1250 |
1380 |
1520 |
Size |
L*W*H (mm) |
700×520×1100 |
800×600×1200 |
800×600×1500 |
1200×900×1600 |
2000×900×1800 |