| Customization: | Available |
|---|---|
| After-sales Service: | Suport After Service |
| Warranty: | 24 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
pure sine wave off grid 1kw 2kw 3kw 12v 24v 48v 220v dc to ac power inverter






| pure sine wave solar inverter | LW 1000 | LW 1500 | LW 2000 | LW 3000 | LW 4000 | LW 5000 | LW 6000 | |
| General Specification | Input Wave form | Sine wave (Utility or Generator) | ||||||
| Nominal voltage | 120VAC | 230VAC | ||||||
| Low voltage trip | 90v + 4% | 184v/154v + 4% | ||||||
| Low voltage reconnect | 100v + 4% | 194v/164v + 4% | ||||||
| High voltage trip | 140v + 4% | 253v + 4% | ||||||
| High voltage reconnect | 135v + 4% | 243v + 4% | ||||||
| Max input AC voltage | 150VAC | 270VAC | ||||||
| Nominal input frequency | 50Hz or 60Hz (Auto detect) | |||||||
| Low freq trip | 47Hz for 50Hz, 57Hz for 60Hz | |||||||
| High freq trip | 55Hz for 50Hz, 65Hz for 60Hz | |||||||
| Output wave form | (Bypass mode) same as input | |||||||
| Overload protection | Circuit breaker | |||||||
| Short circuit protection | Circuit breaker | |||||||
| Transfer switch rating | 30amp or 40amp | |||||||
| Efficiency on line transfer time | 95%+ | |||||||
| Line transfer time | 10ms Typical | |||||||
| Bypass without battery connected | yes | |||||||
| Max bypass current | 30amp or 40amp | |||||||
| Bypass overload current | 35amp or 45amp: Alarm | |||||||
| Inverter Specification Output | Output wave form | Pure sine wave | ||||||
| Output continuous power watts | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 | |
| Output continuous power VA | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 | |
| Power factor | 0.9-1.0 | |||||||
| Nominal output voltage rms | 120/230VAC | |||||||
| Output voltage regulation | 10% rms | |||||||
| Output frequency | 50Hz + 0.3Hz or 60Hz + 0.3Hz | |||||||
| Nominal efficiency | > 88% | |||||||
| Surge ratings | 3000 | 4500 | 6000 | 9000 | 12000 | 15000 | 18000 | |
| Short circuit protection | Yes, fault after 10 seconds | |||||||
| Inverter Specification Input | Nominal input voltage | 12V | 24V | 48V | ||||
| Minimum start voltage | 10V | 20V | 40V | |||||
| Low battery alarm | 10.5V | 21V | 42V | |||||
| Low battery trip | 10V | 20V | 40V | |||||
| High voltage alram | 16V | 32V | 64V | |||||
| Power saver | Below 25watts when enabled | |||||||
| Power saver | Same switched on/off on remote | |||||||
| Charge Mode Specification | Input voltage range | 95-127VAC | 194-243VAC/ 164-243VAC(W) | |||||
| Output voltage range | Dependent on battery type | |||||||
| Charge current | 35A/70A | |||||||
| Battery initial voltage for start up | 0-15.7v for 12v (*2 for 24v; *4 for 48v) | |||||||
| Over charge protection shutdown | 15.7v for 12v (*2 for 24v; *4 for 48v) | |||||||
| Others | Remote control/RS232/USB | Yes, Optional | ||||||
| Size: in mm | 1000/2000/3000 Model: 442*218*179 | |||||||
| 4000/5000/6000 Model: 598*218*179 | ||||||||
| Net weight | LW1000 | LW1500 | LW2000 | LW3000 | LW4000 | LW5000 | LW6000 | |