Model No. | LW1000 | LW1500 | LW2000 | LW3000 | LW4000 | LW5000 | LW6000 |
Nominal Power | 1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W |
AC Input | |||||||
Phase & waveform | Single phase & Pure Sine Wave | ||||||
Voltage | 120VAC/230VAC | ||||||
Acceptable Voltage | 194-243VAC\164-243VAC (wide mode) | ||||||
Line Low Transfer | 85V±4%/184 (154 wide mode±4%) | ||||||
Line Low Return | 95V±4%/194 (164 wide mode±4%) | ||||||
Line high Transfer | 135V±4%/253±4% | ||||||
Line high Return | 127V±4%/243±4% | ||||||
Frequency | 50Hz or 60Hz (auto sensing) | ||||||
Line Low Transfer | 47Hz for 50Hz, 57Hz for 60Hz | ||||||
Line high Transfer | 55Hz for 50Hz, 65Hz for 60Hz | ||||||
Output | |||||||
Phase & waveform | Single phase & Pure Sine Wave (bypass mode sync to input) | ||||||
Voltage | 120/220/230/240VAC (bypass mode sync to input) | ||||||
Voltage Regulation | ±10%rms (bypass mode sync to input) | ||||||
Frequency | 50Hz±0.3Hz (bypass mode sync to input) | ||||||
Peak Power | 3 times of rating power | ||||||
Short Circuit Protection | Yes, shutdown after 10ms | ||||||
Power Factor | 0.9-1.0 | ||||||
DC Input | |||||||
Battery Voltage | 12V/24V | 12V/24V/48V | 24V/48V | ||||
Minimum Start Voltage | 10V for 12V, 20V for 24V, 40V for 48V | ||||||
Low Battery Alarm | 10.5V for 12V, 21V for 24V, 42V for 48V | ||||||
Low Battery Transfer | 10V for 12V, 20V for 24V, 40V for 48V | ||||||
High Voltage Alarm | 16V for 12V, 32V for 24V, 64V for 48V | ||||||
Max Charging Current | 35A/70A | ||||||
Over Charge Voltage | 15.7V for 12V, 31.4V for 24V, 62.8V for 48V | ||||||
Transfer Efficiency | |||||||
Line Mode | >95% | ||||||
Battery Mode | >88% | ||||||
power saver | Available when the load is less than 25 Watts | ||||||
Indicators | |||||||
7-LED Display | From the right to the left,LED1 line mode (green lighting)\LED2 inverter mode | ||||||
(green lighting)\LED3 charging mode(yellow lighting)\LED4 Fully charged | |||||||
(green lighting)\LED5 over heat shutdown(red lighting)\LED6 Overloaded | |||||||
shutdown(red lighting)\LED7 Saving Mode(green lighting) | |||||||
3-LED Display | Charging Mode(green lighting)\inverter mode(green lighting)\ Alarm(red lighting) | ||||||
Switch selector | Saving Mode is on/off when push the switch forwards/backwards, keeping it horisontal is | ||||||
turning the inverter off. | |||||||
Audible Alarm | Sounding when the heatsink's tem is over 105centi-degree and shutdown after 30 seconds. | ||||||
Protections | low battery\over charging\over temp\over load | ||||||
Communications | RS-232/USB(custom-made) | ||||||
Environmental | |||||||
Operating Environment | 0-40centi-degree,0-90%RH(non-condensing) | ||||||
Audible Noise | <60dB | ||||||
Physical | |||||||
Net Weight(KG) | 18 | 20 | 20 | 26 | 48 | 48 | 48 |
Dimension, L X W X H(mm) | 446*218*179 | 605*218*179 |