Customization: | Available |
---|---|
Nature of Source Flow: | Active Inverter |
Certification: | ISO9001, CE, FCC |
Still deciding? Get samples of US$ 275/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. GS series 1-12kw solar hybrid inverter MPPT Solar Inverter PV Inverter
2. Built in 12/24/48vdc 40A or 60A MPPT Solar charge controller,MPPT Solar Inverter PV Inverter
3. Wide AC input voltage range 80-270vac
4. Optional Solar or AC priority function
5. Adjustable charge current
7. Large LCD digital display can show solar and inverter parameter
8. Optional Remote LCD display or Switch panel
9. Generator restart signal(Dry contact)
10. Wall-mounted design
11. 2 years warranty with 2% spare boards
Application
GS series 1-12KW Solar Hybrid Inverter MPPT Solar Inverter PV Inverter Power Inverter Charger pure sine wave inverter with MPPT Controller Inside. It's widely used for wind generator, solar power system, house,vehicle, ship, navigation and places where lack of city power, mobile electricity work and telecommunication device,launch station.
Product Parameters
MODEL (GS Series) |
HV/LV Model | |||||||||
HV Model(4-10KW) LV Model(4-6KW) | ||||||||||
Line Mode Specifications: |
||||||||||
Input Voltage | Input Voltage Waveform | Sinusoidal (utility or generator) | ||||||||
Nominal Input Voltage | LV 120Vac | HV 230Vac | ||||||||
Low Line Disconnect | Normal:85Vac±4% Wide:80Vac±4% | Normal:184Vac±4% Wide:135Vac±4% | ||||||||
Low Line Re-connect | Normal:95Vac±4% Wide:85Vac±4% | Normal:194Vac±4% Wide:145Vac±4% | ||||||||
High Line Disconnect | Normal:136Vac±4% Wide:140Vac±4% | Normal:263Vac±4% Wide:263Vac±4% | ||||||||
High Line Re-connect | Normal:131Vac±4% Wide:135Vac±4% | Normal:253Vac±4% Wide:253Vac±4% | ||||||||
Max AC Input Voltage | 150Vrms | 270Vrms | ||||||||
Input Frequency | Nominal Input Frequency | 50Hz/ 60Hz (Auto detection) | ||||||||
Low Line Frequency Re-connect | 51+0.3Hz for 60Hz; 41+0.3Hz for 50Hz; |
|||||||||
Low Line Frequency Disconnect | 50+0.3Hz for 60Hz; 40+0.3Hz for 50Hz; |
|||||||||
High Line Frequency Re-connect | 64+0.3Hz for 60Hz; 54+0.3Hz for 50Hz; |
|||||||||
High Line Frequency Disconnect | 65+0.3Hz for 60Hz; 55+0.3Hz for 50Hz; |
|||||||||
main functions | Output Voltage Waveform | As same as Input Waveform | ||||||||
Over-Load Protection (SMPS load) | Air switch | |||||||||
Output Short Circuit Protection | Air switch | |||||||||
Max Bypass Overload Current | 40A/50A/80A | |||||||||
Battery Invert Mode Specifications: |
||||||||||
AC output | Output Voltage Waveform | Sine wave | ||||||||
Rated Output Power (KW) | LV:4KW/5KW/6KW | HV: 4KW/5KW/ 6KW/7KW/8KW/10KW |
||||||||
Power Factor | 0.9~1.0 | |||||||||
Nominal Output Voltage (V) | LV:120Vac ±10%rms | HV:230Vac ±10%rms | ||||||||
Nominal Output Frequency (Hz) | 60Hz ± 0.3Hz 50Hz ± 0.3Hz |
|||||||||
DC Voltage | Nominal DC Input Voltage | 24VDC/48VDC | ||||||||
DC Voltage range | 20-31.0Vdc for 24VDC 40-62.0Vdc for 48VDC |
|||||||||
Low Battery Alarm | 21.0Vdc ± 0.6Vdc for 24V battery 42.0Vdc ± 1.2Vdc for 48V battery |
|||||||||
Low DC input Shut-down | 20.0vdc± 0.6Vdc for 24V battery 40.0Vdc ± 1.2Vdc for 48V battery |
|||||||||
High DC input Alarm & Fault | 32Vdc ± 0.6Vdc for 24V battery 64Vdc ± 1.2Vdc for 48V battery |
|||||||||
High DC input Recovery | 31.0Vdc ± 0.6Vdc for 24V battery 62.0Vdc ± 1.2Vdc for 48V battery |
|||||||||
AC Charger | Nominal Charge Current | 35A/50A/70A (5 stages adjustable charging current) | ||||||||
Charge Current Regulation | ± 5Adc | |||||||||
Over Charge Protection | Bat.V≥31.0VDC for 24V battery Bat.V≥62.0VDC for 48V battery beeps 0.5s every 1s & fault after 60s |
|||||||||
Algorithm | Three stage: Boost CC (constant current stage) → Boost CV (constant voltage stage) → Float (constant voltage stage) | |||||||||
Solar charger | Rated Charge Current | 40A | 60A | |||||||
Rated charge battery Voltage type | 24V/48V | 24V | ||||||||
Max.PV open circuit array voltage | 24V for 55Vdc 48V for 110Vdc |
|||||||||
Charger mode | MPPT | |||||||||
PV Low Voltage Re-connect | PV≥Bat.V=3V | |||||||||
PV Low Voltage Disconnect | PV<=Bat.V | |||||||||
Efficiency | ≥97% | |||||||||
Efficiency | Efficiency (Battery Mode) | ≥85% | ||||||||
Efficiency (Line Mode) | >98% | |||||||||
Transfer Time | Ac to Dc | 20ms (Max) | ||||||||
Dc to Ac | 15ms (Max) | |||||||||
System parameter | Over-Load Protection | 110% <load<150%, beeps 0.5s every 1s, and Fault after 60s off the output, Load>150%, beeps 0.5s every 1s, and Fault after 20s. | ||||||||
Output Short Circuit Protection | Current limit (Fault after 10s) | |||||||||
Surge rating (10s) | 1:3 (VA) | |||||||||
Power saver | Load <=25W (Enabled on "P/S auto" setting of Remote control) | |||||||||
Protections | Low battery, over charging, over load , over temp. | |||||||||
Indicators | LED+LCD Display | |||||||||
General Specifications | Operating Temperature Range | 0°C to 40°C | ||||||||
Storage temperature | -15ºC ~60ºC | |||||||||
Operation humidity | 5% to 95%(non-condensing) | |||||||||
Audible Noise | 60dB max | |||||||||
Cooling | Forced air, variable speed fan | |||||||||
Dimension(L*W*H) | 4KW | 5KW | 6KW | 7KW | 8KW | 10KW | ||||
530*400*190mm | 590*420*195mm | |||||||||
Net weight(Kg) | 30.0 | 35.5 | 38.5 | 41.5 | 48.0 | 55.0 |