Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 24months |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
DC to AC 3000W Pure Sine Wave Solar Power Inverter
Main Application
1> Transport equipments: military vehicle, police car, Medical ambulance, ship, traffic lights etc.
2> Industrial equipments: solar energy system, wind power, metal halid lamp, high voltage sodium lamp, etc.
3> Office equipments, computer, printer, display apparatus, duplicator, scanners, digital camera, digital pickup camera, etc.
4> Home equipments: cleaner, fan, lighting, electric cutter, sewing machine, etc.
5> Kitchen appliances: microwave ovens, induction cooker, refrigerator, etc.
6> Electric tools: electric saw, driller, muller, sandblasting machine and punching machine, lawn mower, air compressor, etc.
7> Electronic field: TV, DVD, video games, power amplifiers, auto equipment, monitoring equipment, terminal equipment, server, intelligent platform, satellite communication equipment, etc.
Key feature
1.GS pure sine wave inverter charger 1000w-8000w
2. LED and LCD display
3. 3 times peak power
4. Built-40A MPPT Solar Charger Controller
5. Enhance AC Charger to 20A/35A/50A/70A/90A(According to the inverter model)
6. Selectable input voltage range for home appliances and personal computers
7. Configurable AC/Solar input priority via LCD setting
8. Compatible to mains voltage or generator power
9. Overload and short circuit protection
10. Smart battery charger design for optimized battery performance
11. Dry contact function
12. Optional remote panel available
Good Functions
1. Optional DC/AC priority function
2. Wide AC Input Voltage Range
3. Optional Battery types and Performance
4. Adjustable charging current
5. Built-in MPPT Solar Charge Controller
6. PV Port For connecting Solar Panel directly
Usage
Please assure the Inverter Power is switch off before connection of the battery. Please connect the anode to the red interlink, and cathode pole to the black interlink, be assure of the steady connection, then connect to the load, after all these done, press the turn on button to start inverter.
1. Do not connect the anode and cathode in wrong places.
2. Use in ventilated and dry environment.
3. When output in high voltage, please DO NOT operate with power on.
4. Turn on the Inverter when short circuit is not allowed.
Specification
Model Parameters | GS1000 | GS2000 | GS3000 | GS4000 | GS5000 | GS6000 | GS8K | GS10K | GS12K | |
AC Input | Nominal Power | 1000W | 2000W | 3000W | 4000W | 5000W | 6000W | 8KW | 10KW | 12KW |
Input Voltage Waveform | sinusoidal(utility or generator) | sinusoidal(utility or generator) | sinusoidal(utility or generator) | |||||||
Nominal input Voltage | 120VAC/230VAC | 120VAC/230VAC | 120VAC/230VAC | 120VAC/230VAC | 120VAC/230VAC | 120VAC/230VAC | 230VAC | 230VAC | 230VAC | |
Low Line Disconnect | 85Vac±4%(Normal) or 80Vac±4% (Wide) for 120V 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230V | 85Vac±4%(Normal) or 80Vac±4% (Wide) for 120V 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230V | 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230V | |||||||
Low Line Re-connect | 95Vac±4%(Normal) or 85Vac±4% (Wide) for 120V 194Vac±4%(Normal) or 145Vac±4%(Wide) for 230V | 95Vac±4%(Normal) or 85Vac±4% (Wide) for 120V 194Vac±4%(Normal) or 145Vac±4%(Wide) for 230V | 194Vac±4%(Normal) or 145Vac±4%(Wide) for 230V | |||||||
High Line Disconnect | 136Vac±4%(Normal) or 145Vac±4%(Wide) for 120V 263Vac±4%(Normal) or 263Vac±4%(Wide) for 230V | 136Vac±4%(Normal) or 140Vac±4%(Wide) for 120V 263Vac±4%(Normal) or 263Vac±4%(Wide) for 230V | 263Vac±4%(Normal) or 263Vac±4%(Wide) for 230V | |||||||
Max AC input Voltage | 120V for Max150V, 230V for Max270V | 120V for Max150V, 230V for Max270V | 230V for Max270V | |||||||
Frequency | 50Hz:41-54Hz, 60Hz:51-64Hz | 50Hz:41-54Hz, 60Hz:51-64Hz | 50Hz:41-54Hz, 60Hz:51-64Hz | |||||||
AC Output | Output Voltage Waveform | Sine wave | Sine wave | Sine wave | ||||||
Power Factor | 0.9~1.0 | 0.9~1.0 | 0.9~1.0 | |||||||
Nominal Output Voltage (V) | LV:120Vac ±10%rms, HV:230Vac ±10%rms | LV:120Vac ±10%rms, HV:230Vac ±10%rms | LV:120Vac ±10%rms, HV:230Vac ±10%rms | |||||||
Nominal Output Frequency (Hz) |
50Hz ± 0.3Hz, 50Hz ± 0.3Hz | 50Hz ± 0.3Hz, 60Hz ± 0.3Hz | 50Hz ± 0.3Hz, 60Hz ± 0.3Hz | |||||||
Solar charger |
Rated Charge Current | 40A | 60A | 60A/120A | 60A/120A | |||||
PV Input Voltage range | 15VDC-40VDC for 12VDC, 25VDC-75VDC for 24VDC, 55-145VDC for 48V | 25VDC-75VDC for 24VDC, 55-145VDC for 48V | 55-145VDC for 48V | |||||||
Max.PV open circuit array voltage |
12V for 40Vdc, 24V for 75Vdc, 48V for 145Vdc | 24V for 75Vdc, 48V for 145Vdc | 48V for 145Vdc | |||||||
Charger mode | MPPT | MPPT | MPPT | |||||||
PV Low Voltage Re-connect |
PV≥Bat.V+3V | PV≥Bat.V+3V | PV≥Bat.V+3V | |||||||
PV Low Voltage Disconnect |
PV<=Bat.V | PV<=Bat.V | PV<=Bat.V | |||||||
Efficiency | ≥97% | ≥97% | ≥97% | |||||||
AC Charger | Nominal Charger Current |
20A/35A/50A/70A/90A( 5 stages adjustable charging current) | 20A/35A/50A/70A/90A( 5 stages adjustable charging current) | 20A/35A/50A/70A/90A( 5 stages adjustable charging current) | ||||||
Over charge Protection | Bat.V≥15.5VDC for 12V battery Bat.V≥31.0VDC for 24V battery Bat.V≥62.0VDC for 48V battery beeps 0.5s every 1s & fault after 60s |
Bat.V≥31.0VDC for 24V battery Bat.V≥62.0VDC for 48V battery beeps 0.5s every 1s & fault after 60s |
Bat.V≥62.0VDC for 48V battery beeps 0.5s every 1s & fault after 60s |
|||||||
Efficiency | Efficiency(Battery Mode) | ≥87% | ≥87% | ≥87% | ||||||
Efficiency (Line Mode) | >98% | >98% | >98% | |||||||
Battery Voltage | Nominal DC input Voltage | 12VDC/24VDC/48VDC | 12VDC/24VDC/48VDC | 12VDC/24VDC/48VDC | 24VDC/48VDC | 24VDC/48VDC | 24VDC/48VDC | 48VDC | 48VDC | 48VDC |
Low Battery Alarm | 10.5VDC±0.3VDC for 12VDC 21VDC±0.6VDC for 24VDC 42VDC±1.2VDC for 48VDC |
21VDC±0.6VDC for 24VDC 42VDC±1.2VDC for 48VDC |
42VDC±1.2VDC for 48VDC | |||||||
Low DC input shut & down |
10VDC±0.3VDC for 12VDC 20VDC±0.6VDC for 24VDC 40VDC±1.2VDC for 48VDC |
20VDC±0.6VDC for 24VDC 40VDC±1.2VDC for 48VDC |
40VDC±1.2VDC for 48VDC | |||||||
High DC input Alarm & Fault |
16VDC±0.3VDC for 12VDC 32VDC±0.6VDC for 24VDC 64VDC±1.2VDC for 48VDC |
32VDC±0.6VDC for 24VDC 64VDC±1.2VDC for 48VDC |
64VDC±1.2VDC for 48VDC | |||||||
Transfer Time | AC to DC | 20ms(max) | 20ms(max) | 20ms(max) | ||||||
DC to AC | 15ms(max) | 15ms(max) | 15ms(max) | |||||||
System Parameter | Over-Load Protection | 110%<load<150%, beeps 0.5s every 1s, and Fault after 60s off the output,load>150%, beeps 0.5s every 1s, and Fault after 20s |
110%<load<150%,beeps 0.5s every 1s,and Fault after 60s off the output,load>150%,beeps 0.5s every 1s,and Fault after 20s |
110%<load<150%,beeps 0.5s every 1s,and Fault after 60s off the output,load>150%,beeps 0.5s every 1s,and Fault after 20s |
||||||
Output Short Circuit Protection |
Current limit (Fault after 10s) | Current limit (Fault after 10s) | Current limit (Fault after 10s) | |||||||
Surge Rating(10s) | 1:3(VA) | 1:3(VA) | 1:3(VA) | |||||||
Power Saver | Load≤25W(Enabled on "P/S auto"Setting of Remote control) | Load≤25W(Enabled on "P/S auto"Setting of Remote control) | Load≤25W(Enabled on "P/S auto"Setting of Remote control) | |||||||
Protections | Low battery, over charging, over load, over temp | Low battery, over charging, over load, over temp | Low battery, over charging, over load, over temp | |||||||
Indicators | LED+LCD Display | LED+LCD Display | LED+LCD Display | |||||||
General Specifications |
Operating Temperature Range |
0ºC~40ºC | 0ºC~40ºC | 0ºC~40ºC | ||||||
Storage Temperature | -15ºC~60ºC | -15ºC~60ºC | -15ºC~60ºC | |||||||
Operation humidity | 5% to 95%(non-condensing) | 5% to 95%(non-condensing) | 5% to 95%(non-condensing) | |||||||
Audible Noise | 60dB max | 60dB max | 60dB max | |||||||
cooling | Forced air,variable speed fan | Forced air, variable speed fan | Forced air, variable speed fan | |||||||
Dimension(L*W*H) | 480*336*190mm | 530*400*190mm | 627*416*204mm | |||||||
Net Weight(kg) | 19.5kg | 23.5kg | 28kg | 30kg | 35.5kg | 39kg | 52.5kg | 58.5kg | 66.5kg |
COMPANY SHOW:
1. A professional manufacturer which cover UPS,inverters and batteries with 8 years experience
2. Own 68 countries and market over the world
3. Welcome OEM, high quality with CE&ISO certificate
2 Years Warranty with 2% spare part and technical support, excellent pre-sale and after-sale service.
OEM or Special design are available like OEM logo, package and so on
FAQ:
Q 1. What's the payment terms and payment method ?
A. We accept L/C, T/T, Credit Card, Western Union, Money Gram, etc.
Usually 30% deposit, 70% before shipment.
Q 2. How's the delivery time ?
A. It usually takes about 3-10 days after payment arrived.
Q 3. How about package ?
A. For the small UPS and the inverters less than 30kg will be packed in foams and cartons. For the big UPS and inverters heavier than 30kg will be packed in pallets or wood boxes .
Q 4. Would you accept to print our logo and design ?
A. Yes, we can print your logo on the inverters, UPS and cartons. Also welcomed your own design of these inverters and UPS.
Q 5. What kind of certificates you have ?
A. For company have ISO9001, ISO14001, TUV and SGS factory certification.
For UPS and power inverters, we have CE,IEC, KC and ETL, etc.
Q6. When the product have problem, how to solve it ?
A. We have a professional after-sales team, in case of any problems, first contact us to help you solve, we have a 24 months warranty and lifetime technical support. We will track product usage until you are satisfied.