Model | CX2K | CX3K | C2KL | C3KL | ||
Capacity | VA/W | 2000VA/1600W | 3000VA/2400W | 2000VA/1600W | 3000VA/2400W | |
Input | Nominal Voltage | 200/208/220/230/240VAC | ||||
Voltage Range | 115~300VAC | |||||
Harmonic Distortion | <10% (Nonlinear load) | |||||
Power Factor | 0.98 | |||||
Frequency Range | 50Hz: 46~54Hz;60Hz: 56~64Hz | |||||
Output | Voltage | 200/ 208/ 220/ 230/ 240 (1±1%)VAC | ||||
Frequency | 50/60Hz (Adjustable); 50Hz AC Mode: Follow AC Mode (AC Range 46~54Hz); Battery Mode: 50Hz (1±0.2%) 60Hz AC Mode: Follow AC Mode (AC Range 56~64Hz); Battery Mode: 60Hz (1±0.2%) | |||||
Wave Form | Pure sine wave | |||||
Power Factor | 0.8 | |||||
Harmonic Distortion | ≤4% (Linear load); ≤7% (Nonlinear load) | |||||
Overload Capacity | 105%~150% 45S~25S; 150%~200% 25s~300ms; ≥200% 200ms | |||||
Current Crest Ratio | 3∶1 | |||||
Connections | IEC320*6 | IEC320*3& Terminal block | IEC320*6 | IEC320*3& Terminal block | ||
Efficiency | Battery Mode | 83% | ||||
AC Mode | 87% | |||||
Battery | Type | Sealed free maintenance lead acid battery | ||||
Nominal DC voltage | 48VDC | 72VDC | 72VDC | 96VDC | ||
Quantity | 12VDC×4 | 12VDC×6 | 12VDC×6 | 12VDC×8 | ||
Backup Time (Full Load) | >5min | >4.5min | Depends on requested Back-up time | |||
(Built in batteries12V7AH) | Depends on requested Back-up time | |||||
Charge Current (Max) | 1A | 5A | ||||
Charge Voltage (VDC) | 54.8V±0.4VDC | 82.2V±0.6VDC | 82.2V±0.6VDC | 110±0.6VDC | ||
Recharge Time | 5 hours filling to 90% (standard) | Depends on external battery capacity (long-term) | ||||
Bypass | Automatic Transfer | On overload and UPS failure | ||||
Before UPS Power-on | Default "ON" user adjustable to "YES" | |||||
Transfer Time | 0 ms; Less than 4ms from inverter to bypass and vice versa | |||||
indicators | LCD Display | UPS status, Battery capacity, loading, Fault code (LCD: I/P&O/P voltage&frequency, Battery voltage) | ||||
Audible | Bypass, On battery mode, Battery low, Overload, Fault | |||||
Acoustic Noise | At 1 Meter Distance | <50dB | ||||
Communications | Intelligent RS232 serial port | Software support Windows family software, Linux, Sun network operating system, IBM Aix, Compaq True64 SGI IRIX, FreeBSD, HP-UX and MAC | ||||
SNMP (Optional) | Remote control UPS through SNMP management and Internet | |||||
USB (Optional) | Windows family software and Mac OS | |||||
Environmental | Operating Temperature | 0~40ºC | ||||
Operating Humidity | 20~90% (No condensing) | |||||
Physical Parameter | L*W*H (mm) | 448*192*341 | ||||
Net Weight (Kgs) | 17.5 | 22 | 9.5 | 10 |