10kw AC Charger Solar Power off Grid Hybrid Pure Sine Wave Inverter

Product Details
Customization: Available
Nature of Source Flow: Passive inverter
Certification: CCC, ISO9001, RoHS, CE, SAA
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
100% Finished Products Inspection
The supplier inspects 100% of finished products.
R&D Capabilities
The supplier has 15 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
to see all verified strength labels (28)
  • 10kw AC Charger Solar Power off Grid Hybrid Pure Sine Wave Inverter
  • 10kw AC Charger Solar Power off Grid Hybrid Pure Sine Wave Inverter
  • 10kw AC Charger Solar Power off Grid Hybrid Pure Sine Wave Inverter
  • 10kw AC Charger Solar Power off Grid Hybrid Pure Sine Wave Inverter
  • 10kw AC Charger Solar Power off Grid Hybrid Pure Sine Wave Inverter
  • 10kw AC Charger Solar Power off Grid Hybrid Pure Sine Wave Inverter
Find Similar Products
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
GS
Output Power
1000W-12000W
Grid Type
off-Grid Inverter
Output Type
Single
Circuit Topologies
Full-Bridge Type
Nature of Wave String
Sine Wave Inverter
Type
DC/AC Inverters
Applications
Pumps, Motor, Welding Machine etc
LED+LCD Display
Voltage, Frequency, Battery Ststus, PV
Rated Charge Current
60A Power Inverter
Max PV Open Array Voltage
12V for 40vdd, 24V for 55 VDC, 48V for 145VDC
Battery Voltage
12/24/48VDC ( Inverter Inverex)
Cooling
Forced Air, Variable Speed Fan
Warranty
2 Years
Name
off Gris Hybrid Low Frequency Inverter
Max AC Input Voltage
120VAC for Max 150VAC 230VAC for Max270VAC
OEM/ODM
Available
Transport Package
Carton/Wooden Case
Specification
CE
Trademark
ZLPOWER
Origin
Shenzhen
HS Code
8504409900
Production Capacity
10000/Month

Product Description

10kw AC Charger Solar Power off Grid Hybrid Pure Sine Wave Inverter
10KW  Solar Power System off Grid Hybrid Pure Sine Wave Power Inverter AC Charger Inverter
10kw AC Charger Solar Power off Grid Hybrid Pure Sine Wave Inverter

10kw AC Charger Solar Power off Grid Hybrid Pure Sine Wave Inverter

Key features:
♦ GS Series AC/Solar charging hybrid off grid inverter.
♦ LED/LCD display, Enhanced functions setting via LCD.Man-machine intelligent design.
♦ Built-in 40A/60A optional MPPT solar charger controller.
♦ Remote external display panel realize remote operation.
♦ 5 stages adjustable AC charging current. AC charging also can be closed.
♦ AC/DC priority modes can be set.
♦ Generator restart signal. (Dry contact).
♦ 3 times peak power. Strong loading capacity.
♦ Overload, output short-circuit protection.

Specification:
                                                                    Model                                                 Parameters GS1000 GS2000 GS3000 GS4000 GS5000 GS6000 GS8K GS10K GS12K
AC  Input Nominal Power 1000W 2000W 3000W 4000W 5000W 6000W 8KW 10KW 12KW
Input Voltage Waveform sinusoidal(utility or generator) sinusoidal(utility or generator) sinusoidal(utility or generator)
Nominal input Voltage 120VAC/230VAC 120VAC/230VAC 120VAC/230VAC 120VAC/230VAC 120VAC/230VAC 120VAC/230VAC 230VAC 230VAC 230VAC
Low Line  Disconnect 85Vac±4%(Normal) or 80Vac±4% (Wide) for 120V                                                           184Vac±4%(Normal) or 135Vac±4%(Wide) for 230V 85Vac±4%(Normal) or 80Vac±4% (Wide) for 120V                                                                 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230V 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230V
Low Line  Re-connect 95Vac±4%(Normal) or 85Vac±4% (Wide) for 120V                                                           194Vac±4%(Normal) or 145Vac±4%(Wide) for 230V 95Vac±4%(Normal) or 85Vac±4% (Wide) for 120V                                                           194Vac±4%(Normal) or 145Vac±4%(Wide) for 230V 194Vac±4%(Normal) or 145Vac±4%(Wide) for 230V
High Line  Disconnect 136Vac±4%(Normal) or 145Vac±4%(Wide) for 120V                                                       263Vac±4%(Normal) or 263Vac±4%(Wide) for 230V 136Vac±4%(Normal) or 140Vac±4%(Wide) for 120V                                                             263Vac±4%(Normal) or 263Vac±4%(Wide) for 230V 263Vac±4%(Normal) or 263Vac±4%(Wide) for 230V
Max AC input Voltage 120V for Max150V, 230V for Max270V 120V for Max150V, 230V for Max270V 230V for Max270V
Frequency 50Hz:41-54Hz, 60Hz:51-64Hz 50Hz:41-54Hz, 60Hz:51-64Hz 50Hz:41-54Hz, 60Hz:51-64Hz
AC Output Output Voltage Waveform Sine wave Sine wave Sine wave
Power Factor 0.9~1.0 0.9~1.0 0.9~1.0
Nominal Output Voltage (V) LV:120Vac ±10%rms, HV:230Vac ±10%rms LV:120Vac ±10%rms, HV:230Vac ±10%rms LV:120Vac ±10%rms, HV:230Vac ±10%rms
Nominal Output
Frequency   (Hz)
50Hz ± 0.3Hz, 50Hz ± 0.3Hz 50Hz ± 0.3Hz, 60Hz ± 0.3Hz 50Hz ± 0.3Hz, 60Hz ± 0.3Hz
Solar
charger
Rated Charge Current 40A 60A  60A/120A  60A/120A
PV Input Voltage range 15VDC-40VDC for 12VDC, 25VDC-75VDC for 24VDC, 55-145VDC for 48V 25VDC-75VDC for 24VDC, 55-145VDC for 48V 55-145VDC for 48V
Max.PV open circuit
array voltage
12V for 40Vdc, 24V for 75Vdc, 48V for 145Vdc    24V for 75Vdc, 48V for 145Vdc    48V for 145Vdc   
Charger  mode MPPT MPPT MPPT
PV Low Voltage
Re-connect
PV≥Bat.V+3V PV≥Bat.V+3V PV≥Bat.V+3V
PV Low  Voltage
Disconnect
PV<=Bat.V PV<=Bat.V PV<=Bat.V
Efficiency ≥97% ≥97% ≥97%
AC  Charger Nominal Charger
Current
20A/35A/50A/70A/90A( 5 stages adjustable charging current) 20A/35A/50A/70A/90A(  5 stages adjustable charging current) 20A/35A/50A/70A/90A( 5 stages adjustable charging current)
Over charge Protection Bat.V15.5VDC for 12V battery
Bat.V≥31.0VDC for 24V battery
Bat.V≥62.0VDC for 48V battery
beeps 0.5s every 1s & fault after 60s
Bat.V≥31.0VDC for 24V battery
Bat.V≥62.0VDC for 48V battery
beeps 0.5s every 1s & fault after 60s
Bat.V≥62.0VDC for 48V battery
beeps 0.5s every 1s & fault after 60s
Efficiency Efficiency(Battery Mode) ≥87% ≥87% ≥87%
Efficiency (Line Mode) >98% >98% >98%
Battery  Voltage Nominal DC input Voltage 12VDC/24VDC/48VDC 12VDC/24VDC/48VDC 12VDC/24VDC/48VDC 24VDC/48VDC 24VDC/48VDC 24VDC/48VDC 48VDC 48VDC 48VDC
Low Battery Alarm 10.5VDC±0.3VDC  for  12VDC
21VDC±0.6VDC  for  24VDC
42VDC±1.2VDC  for  48VDC
21VDC±0.6VDC  for  24VDC
42VDC±1.2VDC  for  48VDC
42VDC±1.2VDC  for  48VDC
Low DC input
shut & down
10VDC±0.3VDC  for  12VDC
20VDC±0.6VDC  for  24VDC
40VDC±1.2VDC  for  48VDC
20VDC±0.6VDC  for  24VDC
40VDC±1.2VDC  for  48VDC
40VDC±1.2VDC  for  48VDC
High DC input
Alarm & Fault
16VDC±0.3VDC  for  12VDC
32VDC±0.6VDC  for  24VDC
64VDC±1.2VDC  for  48VDC
32VDC±0.6VDC  for  24VDC
64VDC±1.2VDC  for  48VDC
64VDC±1.2VDC  for  48VDC
Transfer Time AC to DC 20ms(max) 20ms(max) 20ms(max)
DC to AC 15ms(max) 15ms(max) 15ms(max)
System Parameter Over-Load Protection 110%<load<150%, beeps 0.5s every 1s, and Fault after 60s off
the output,load>150%, beeps 0.5s every 1s, and Fault after 20s
110%<load<150%,beeps 0.5s every 1s,and Fault after 60s off
the output
,load>150%,beeps 0.5s every 1s,and Fault after 20s
110%<load<150%,beeps 0.5s every 1s,and Fault after 60s off
the output
,load>150%,beeps 0.5s every 1s,and Fault after 20s
Output Short Circuit
Protection
Current limit (Fault after 10s) Current  limit (Fault after 10s) Current  limit (Fault after 10s)
Surge Rating(10s) 1:3(VA) 1:3(VA) 1:3(VA)
Power Saver Load≤25W(Enabled on "P/S auto"Setting of Remote control) Load≤25W(Enabled on "P/S auto"Setting of Remote control) Load≤25W(Enabled on "P/S auto"Setting of Remote control)
Protections Low battery, over charging, over load, over temp Low battery,  over charging,  over load,  over temp Low battery,  over charging,  over load,  over temp
Indicators LED+LCD  Display LED+LCD  Display LED+LCD  Display
General
Specifications

 
Operating Temperature
Range
0ºC~40ºC 0ºC~40ºC 0ºC~40ºC
Storage Temperature -15ºC~60ºC -15ºC~60ºC -15ºC~60ºC
Operation humidity 5% to 95%(non-condensing) 5% to 95%(non-condensing) 5% to 95%(non-condensing)
Audible Noise 60dB max 60dB max 60dB max
cooling Forced  air,variable speed  fan Forced  air, variable speed  fan Forced  air, variable speed  fan
Dimension(L*W*H) 480*336*190mm 530*400*190mm 627*416*204mm
Net Weight(kg) 19.5kg 23.5kg 28kg 30kg 35.5kg 39kg 52.5kg 58.5kg 66.5kg
Company Profile

10kw AC Charger Solar Power off Grid Hybrid Pure Sine Wave Inverter
10kw AC Charger Solar Power off Grid Hybrid Pure Sine Wave Inverter
10kw AC Charger Solar Power off Grid Hybrid Pure Sine Wave Inverter
FAQ:
Q 1. What's the payment terms and payment method ? 
A. We accept L/C, T/T, Credit Card, Western Union, Money Gram, etc.

Usually 30% deposit, 70% before shipment.

Q 2. How's the delivery time ?
A.  It  usually takes about 3-10 days after payment arrived.

Q 3. How about package ?
A. For the small UPS and the inverters less than 30kg will be packed in foams and cartons. For the big UPS and inverters heavier than 30kg will be packed in pallets or wood boxes .


Q 4. Would you accept to print our logo and design ?
A. Yes, we can print your logo on the inverters, UPS and cartons. Also welcomed your own design of these inverters and UPS.

Q 5. What kind of certificates you have ?
A. For company have ISO9001, ISO14001, TUV and SGS factory certification.

For UPS and power inverters, we have CE,IEC, KC and ETL, etc.

Q6. When the product have problem, how to solve it ?
A. We have a professional after-sales team, in case of any problems, first contact us to help you solve, we have a 24 months warranty and lifetime technical support. We will track product usage until you are satisfied.


CONTACT WAY:
https://zlpower.en.made-in-china.com/contact-info.html

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier