MODEL (GS Series) |
HV/LV Model | |||||||||
HV Model(4-10KW) LV Model(4-6KW) | ||||||||||
Line Mode Specifications: |
||||||||||
Input Voltage |
Input Voltage Waveform | Sinusoidal (utility or generator) | ||||||||
Nominal Input Voltage | LV 120VAC | HV 230VAC | ||||||||
Low Line Disconnect | Normal: 85VAC±4% Wide: 80VAC±4% | Normal: 184VAC±4% Wide: 135VAC±4% | ||||||||
Low Line Re-connect | Normal: 95VAC±4% Wide: 85VAC±4% | Normal: 194VAC±4% Wide: 145VAC±4% | ||||||||
High Line Disconnect | Normal: 136VAC±4% Wide: 140VAC±4% | Normal: 263VAC±4% Wide: 263VAC±4% | ||||||||
High Line Re-connect | Normal: 131VAC±4% Wide: 135VAC±4% | Normal: 253VAC±4% Wide: 253VAC±4% | ||||||||
Max AC Input Voltage | 150Vrms | 270Vrms | ||||||||
Input Frequency | Nominal Input Frequency | 50Hz/ 60Hz (Auto detection) | ||||||||
Low Line Frequency Re-connect | 51+0.3Hz for 60Hz; 41+0.3Hz for 50Hz; |
|||||||||
Low Line Frequency Disconnect | 50+0.3Hz for 60Hz; 40+0.3Hz for 50Hz; |
|||||||||
High Line Frequency Re-connect | 64+0.3Hz for 60Hz; 54+0.3Hz for 50Hz; |
|||||||||
High Line Frequency Disconnect | 65+0.3Hz for 60Hz; 55+0.3Hz for 50Hz; |
|||||||||
Main functions | Output Voltage Waveform | As same as Input Waveform | ||||||||
Over-Load Protection (SMPS load) | Air switch | |||||||||
Output Short Circuit Protection | Air switch | |||||||||
Max Bypass Overload Current | 40A/50A/80A | |||||||||
Battery Invert Mode Specifications: |
||||||||||
AC output |
Output Voltage Waveform | Sine wave | ||||||||
Rated Output Power (KW) | LV: 4KW/5KW/6KW | HV: 4KW/5KW/ 6KW/7KW/8KW/10KW |
||||||||
Power Factor | 0.9~1.0 | |||||||||
Nominal Output Voltage (V) | LV: 120VAC ±10%RMS | HV: 230VAC ±10%RMS | ||||||||
Nominal Output Frequency (Hz) | 60Hz ± 0.3Hz 50Hz ± 0.3Hz |
|||||||||
DC Voltage | Nominal DC Input Voltage | 24VDC/48VDC | ||||||||
DC Voltage range | 20-31.0VDC for 24VDC 40-62.0VDC for 48VDC |
|||||||||
Low Battery Alarm | 21.0VDC ± 0.6VDC for 24V battery 42.0VDC ± 1.2VDC for 48V battery |
|||||||||
Low DC input Shut-down | 20.0VDC± 0.6VDC for 24V battery 40.0VDC ± 1.2VDC for 48V battery |
|||||||||
High DC input Alarm & Fault | 32VDC ± 0.6VDC for 24V battery 64VDC ± 1.2VDC for 48V battery |
|||||||||
High DC input Recovery | 31.0VDC ± 0.6VDC for 24V battery 62.0VDC ± 1.2VDC for 48V battery |
|||||||||
AC Charger | Nominal Charge Current | 35A/50A/70A (5 stages adjustable charging current) | ||||||||
Charge Current Regulation | ± 5ADC | |||||||||
Over Charge Protection | Bat. V≥31.0VDC for 24V battery Bat. V≥62.0VDC for 48V battery Beeps 0.5s every 1s & fault after 60s |
|||||||||
Algorithm | Three stage: Boost CC (constant current stage) → Boost CV (constant voltage stage) → Float (constant voltage stage) | |||||||||
Solar charger | Rated Charge Current | 40A | 60A | |||||||
Rated charge battery Voltage type | 24V/48V | 24V | ||||||||
Max. PV open circuit array voltage | 24V for 55VDC 48V for 110VDC |
|||||||||
Charger mode | MPPT | |||||||||
PV Low Voltage Re-connect | PV≥Bat. V=3V | |||||||||
PV Low Voltage Disconnect | PV<=Bat. V | |||||||||
Efficiency | ≥97% | |||||||||
Efficiency | Efficiency (Battery Mode) | ≥85% | ||||||||
Efficiency (Line Mode) | >98% | |||||||||
Transfer Time | AC to DC | 20ms (Max) | ||||||||
DC to AC | 15ms (Max) | |||||||||
System parameter | Over-Load Protection | 110% 150%, beeps 0.5s every 1s, and Fault after 20s. Output Short Circuit ProtectionCurrent limit (Fault after 10s) | ||||||||
Surge ratin | G (10s)1: 3 (VA)Power SA | |||||||||
VerLoad <=25W (En | Ab | |||||||||
Le | D on "P/S auto" setting of Remote control) | |||||||||
Protections | Low battery, over charging, over load, over temp. | |||||||||
Indicators | LED+LCD Display | |||||||||
General Specifications | Operating Temperature Range | 0°C to 40°C | ||||||||
Storage temperature | -15ºC ~60ºC | |||||||||
Operation humidity | 5% to 95%(non-condensing) | |||||||||
Audible Noise | 60dB max | |||||||||
Cooling | Forced air, variable speed fan | |||||||||
Dimension(L*W*H) | 4KW | 5KW | 6KW | 7KW | 8KW | 10KW | ||||
530*400*190mm | 590*420*195mm | |||||||||
Net weight(Kg) | 30.0 | 35.5 | 38.5 | 41.5 | 48.0 | 55.0 | ||||