• Power Supply 20kVA-80kVA 0.8 Output and N+X Parallel 3phase High Frequency Online UPS
  • Power Supply 20kVA-80kVA 0.8 Output and N+X Parallel 3phase High Frequency Online UPS
  • Power Supply 20kVA-80kVA 0.8 Output and N+X Parallel 3phase High Frequency Online UPS
  • Power Supply 20kVA-80kVA 0.8 Output and N+X Parallel 3phase High Frequency Online UPS
  • Power Supply 20kVA-80kVA 0.8 Output and N+X Parallel 3phase High Frequency Online UPS
  • Power Supply 20kVA-80kVA 0.8 Output and N+X Parallel 3phase High Frequency Online UPS

Power Supply 20kVA-80kVA 0.8 Output and N+X Parallel 3phase High Frequency Online UPS

Phase: 3phase 4 Line + Earth Line
Type: On-line
Protection: Overload, Short Circuit, Overcurrent, Overvoltage
Application: Industry
Classification: Lighting
Standby Time: Long-acting Machine
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
EX3320K~EX3340K
Standby UPS
Sine Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Centralized Model
UPS Technology
MCU (Freescale) +DSP (Ti) Technology
Input Voltage
210-475VAC
Battery
Valve-Regulated Free Maintenance
Output Voltage
380/410/415VAC
Operating Humidity
95% Non Condesing
Transport Package
Each Unit Pack With a Carton Box
Specification
CE & ISO
Trademark
ZLPOWER
Origin
China
HS Code
8504402000
Production Capacity
50, 000 PCS/Month

Product Description

Three Phase High Frequency Online UPS/ 3phase UPS
1. 20K~80kVA 0.8output power factor
2. N+X parallel redundant UPS power supply
3. CPU Control
4. DSP Chip
 Power Supply 20kVA-80kVA 0.8 Output and N+X Parallel 3phase High Frequency Online UPS
Power Supply 20kVA-80kVA 0.8 Output and N+X Parallel 3phase High Frequency Online UPS

Description:
EX33 High frequency online UPS is applicable to small and medium-sized data centers, network management center, computer rooms for enterprises, or able to provide solutions to conditions like voltage instantaneous drop-off or damping concussion, high-voltage pulse, voltage pulsation, surge voltage, harmonic distortion, and frequency fluctuation. 
 
Features:
N+X parallel redundancy (compatible to battery share in the parallel mode)
The maximum of the inbuilt parallel mode is 8 UPS without any other external accessories, which helps the customer to extend the system capacity with low cost. N stands for the minimum amount of UPS in the load and X stands for the amount of redundant UPS in the system. The bigger the number of X is, the higher the reliability of the system. 
The advanced controlling strategy is adopted to save the customer's investment by sharing a battery unit in the parallel redundancy mode. 
Intelligent management of battery charging and discharging 
The CPU controlled advanced intelligent charging of battery enables the UPS's charger to rectify the charging parameter, and provide the optimum charging modes in the answer to the environment, types and amounts of cells, and the using condition of the battery. The scientific charging mode extends the battery's service lifetime. The optional addition to charging units shortens the time duration for the battery units recharging. 
Frontal-board operation and maintenance 
The full consideration of customer's efficiency in using the UPS is embodied in the module design and frontal-board maintenance, which saves time for repairing and improves the machine's usability. 
Twin-channel line input 
The UPS provides customer security in power supply with intelligent choice between two-line input or one-line input according to the actual condition. 
Remote monitoring  
Communication interfaces like RS232/RS485, Intelligent Slot are provided and CMC, WebPower cards of ZLPOWER Company are available for the realization of remote management and monitoring. In addition, the optional AS400 card is suitable for the connection of stem point, which enriches the customer's choice out of the monitoring demand. 
High-efficient DSP chip
The digital Ti DSP controlling chip provides precise data processing capability with excellent performance in output and reliability. 
Outstanding electric property 
The efficiency of the machines is as high as 93% and reaches over 98% in the ECO mode, which can help to reduce the power loss of UPS. 
The EX33 series UPS is designed according to China's power grid with a broader range of input voltage from 210VAC to 475VAC, which ensures that it can be applicable in the awful grid environment or different power supple equipment like generator with its extraordinary input frequency. 
     
Flexible battery arrangement 
Flexible arrangement of the amount of accumulators in each battery (32, 30, or 28) can be achieved through the parameter resetting in the EX33 series UPS, which effectively solves the question that the damage of some individual cell may influence the life of the whole battery unit by eliminating the damaged ones from the unit in the process of using UPS.

 
 
Product Series HP33   10-80KVA
Model HP3310K HP3315K HP3320K HP3330K HP3340K HP3360K HP3380K
Capacity (VA/W) 10KVA/8KW 15KVA/12KW 20KVA/16KW 30KVA/24KW 40KVA/32KW 60KVA/48KW 80KVA/64KW
Rectifier Input RectifierType IGBT-based Vector Controlled PFC(PF Corrected)
Input Voltage 380/400/415VAC(Accepted from 305 to 477 without battery use)
Input Frequency 50HZ or 60HZ(Accepted range from 40 to 70)
Input Current THD <3%(without any Filter)
Input Power Factor ≥0.99(without any Filter)
Power Walk-In 5 to 30s (selectable)
Bypass Input Input Voltage 380/400/415VAC
Battery Battery Type VRLA(Valve Regulated Lead Acid) or Wet/Flooded or NiCd
End-Cell Voltage 1.60-1.90VDC (for VRLA)
DC Ripple Current(float) <5%(of DC10 AH capacity )RMS value
DC Ripple Voltage(float &const V Ch) <1% (RMS value)
Temp.Comp.
Charge
Standard(where internal batteries 10,15,20,30Kva) and Optional(for all other battery configurations)
Output Inverter Type IGBT-based Vector,Repetitive&PI Controlled
Output Voltage 380/400/415VAC±5 Regulation(3-phase RMS average)
Output Frequency 50/60HZ(±0.05)
Output Voltage THD 1%(max)
Max.Load Crest Factor 3:1(compliant with IEC62040-3)
Transient Volt.Resp 10ms to recover ±0.5 of Nominal Voltage for 0% to 100% or 100% to 0% step load
Max.Leading PF Load Up to 0.9
Voltage Displacement 120º±10º(with 100% unbalanced load)
Overload 110% for 60 minutes, 125% for 10 minutes, 150% for 1 minute.
Efficiency AC-AC Up to 96%
EMC-Class Class-A(Applicable for both Radiated &Conducted)
Environmental Storage Temp. -20-70 Centigrade (UPS)&-20-30 Centigrade (Battery)
Operating Temp 0-40 Centigrade (UPS)&25±5 Centigrade (Battery)
Relative Humidity 0-95%(non-condensing)
Maximun Altitude above Mean Sea Level 1000m(as per IEC 62040/3)
Main unit Dimension(W*D*H)mm 420*643*956 420*643*956 420*643*956 470*710*1150 470*710*1150 673*835*1550 673*835*1550
Wight(KG) 115 117 122 160 164 450 510
UPS Enclosure IP IP20 (even with open front door)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Management System Certification
ISO9001:2015, ISO14001:2015
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment