| Customization: | Available |
|---|---|
| Nature of Source Flow: | Passive inverter |
| Certification: | CCC, ISO9001, RoHS, CE, SAA |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

| Model No. | LW1000 | LW1500 | LW2000 | LW3000 | LW4000 | LW5000 | LW6000 | LW7000 | LW8000 |
| Nominal Power | 1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W | 7000W | 8000W |
| AC Input | |||||||||
| Phase & waveform | Single phase & Pure Sine Wave | ||||||||
| Voltage | 120VAC/230VAC | 220,230,240VAC | |||||||
| Acceptable Voltage | 194-243VAC\164-243VAC (wide mode) | ||||||||
| Line Low Transfer | 85V±4%/184 (154 wide mode±4%) | ||||||||
| Line Low Return | 95V±4%/194 (164 wide mode±4%) | ||||||||
| Line high Transfer | 135V±4%/253±4% | ||||||||
| Line high Return | 127V±4%/243±4% | ||||||||
| Frequency | 50Hz or 60Hz (auto sensing) | ||||||||
| Line Low Transfer | 47Hz for 50Hz, 57Hz for 60Hz | ||||||||
| Line high Transfer | 55Hz for 50Hz, 65Hz for 60Hz | ||||||||
| Output | |||||||||
| Phase & waveform | Single phase & Pure Sine Wave (bypass mode sync to input) | ||||||||
| Voltage | 120/220/230/240VAC (bypass mode sync to input) | 220,230,240VAC | |||||||
| Voltage Regulation | ±10%rms (bypass mode sync to input) | ||||||||
| Frequency | 50Hz±0.3Hz (bypass mode sync to input) | ||||||||
| Peak Power | 3 times of rating power | ||||||||
| Short Circuit Protection | Yes, shutdown after 10ms | ||||||||
| Power Factor | 0.9-1.0 | ||||||||
| DC Input | |||||||||
| Battery Voltage | 12V/24V | 12V/24V/48V | 24V/48V | 48/72V | |||||
| Minimum Start Voltage | 10V for 12V, 20V for 24V, 40V for 48V | ||||||||
| Low Battery Alarm | 10.5V for 12V, 21V for 24V, 42V for 48V | ||||||||
| Low Battery Transfer | 10V for 12V, 20V for 24V, 40V for 48V | ||||||||
| High Voltage Alarm | 16V for 12V, 32V for 24V, 64V for 48V | ||||||||
| Max Charging Current | 35A/70A | ||||||||
| Over Charge Voltage | 15.7V for 12V, 31.4V for 24V, 62.8V for 48V | ||||||||
| Transfer Efficiency | |||||||||
| Line Mode | >95% | ||||||||
| Battery Mode | >88% | ||||||||
| power saver | Available when the load is less than 25 Watts | ||||||||
| Indicators | |||||||||
| 7-LED Display | From the right to the left,LED1 line mode (green lighting)\LED2 inverter mode | ||||||||
| (green lighting)\LED3 charging mode(yellow lighting)\LED4 Fully charged | |||||||||
| (green lighting)\LED5 over heat shutdown(red lighting)\LED6 Overloaded | |||||||||
| shutdown(red lighting)\LED7 Saving Mode(green lighting) | |||||||||
| 3-LED Display | Charging Mode(green lighting)\inverter mode(green lighting)\ Alarm(red lighting) | ||||||||
| Switch selector | Saving Mode is on/off when push the switch forwards/backwards, keeping it horisontal is | ||||||||
| turning the inverter off. | |||||||||
| Audible Alarm | Sounding when the heatsink's tem is over 105C and shutdown after 30 seconds. | ||||||||
| Protections | low battery\over charging\over temp\over load | ||||||||
| Communications | RS-232/USB(custom-made) | ||||||||
| Environmental | |||||||||
| Operating Environment | 0-40C,0-90%RH(non-condensing) | ||||||||
| Audible Noise | <60dB | ||||||||
| Physical | |||||||||
| Net Weight(KG) | 18 | 20 | 20 | 26 | 48 | 48 | 48 | 55 | 60 |
| Dimension, L X W X H(mm) | 446*218*179 | 605*218*179 | |||||||


FAQ: