Low frequency MPPT solar inverter solar hybrid inverter(Based on Transformer)
1. GS 1-12KW pure sine wave inverter with MPPT solar charge controller, LCD can show solar and inverter parameters
2. GW Plus 1-12KW pure sine wave inverter with MPPT solar charge controller, LCD can only show inverter parameters
Main Features
1. Compatible to mains or generator power
2. AC and solar charger
3. Wide dc input votlage 80-270vac
4. Compatible to mains or generator power
5. Selectable AC or solar priority function6. Adjustable charging current
6. Generator restart signal
7. 3 times peak power
8. GS 1-12KW LCD display can show Solar generation and Inverter parameters, while GW plus 1-12kw can only show inverter parameters..
Application
ZLPOWER 1-12kw power inverter off grid solar inverter hybrid inverter can work with solar energy, generator and AC mains. They are widely used for home appliances and office devices for long time backup.
Specifications
GS 1-12kw
MODEL (GS Series) |
HV/LV Model | |||||||||
HV Model(4-10KW) LV Model(4-6KW) | ||||||||||
Line Mode Specifications: |
||||||||||
Input Voltage | Input Voltage Waveform | Sinusoidal (utility or generator) | ||||||||
Nominal Input Voltage | LV 120Vac | HV 230Vac | ||||||||
Low Line Disconnect | Normal:85Vac±4% Wide:80Vac±4% | Normal:184Vac±4% Wide:135Vac±4% | ||||||||
Low Line Re-connect | Normal:95Vac±4% Wide:85Vac±4% | Normal:194Vac±4% Wide:145Vac±4% | ||||||||
High Line Disconnect | Normal:136Vac±4% Wide:140Vac±4% | Normal:263Vac±4% Wide:263Vac±4% | ||||||||
High Line Re-connect | Normal:131Vac±4% Wide:135Vac±4% | Normal:253Vac±4% Wide:253Vac±4% | ||||||||
Max AC Input Voltage | 150Vrms | 270Vrms | ||||||||
Input Frequency | Nominal Input Frequency | 50Hz/ 60Hz (Auto detection) | ||||||||
Low Line Frequency Re-connect | 51+0.3Hz for 60Hz; 41+0.3Hz for 50Hz; |
|||||||||
Low Line Frequency Disconnect | 50+0.3Hz for 60Hz; 40+0.3Hz for 50Hz; |
|||||||||
High Line Frequency Re-connect | 64+0.3Hz for 60Hz; 54+0.3Hz for 50Hz; |
|||||||||
High Line Frequency Disconnect | 65+0.3Hz for 60Hz; 55+0.3Hz for 50Hz; |
|||||||||
main functions | Output Voltage Waveform | As same as Input Waveform | ||||||||
Over-Load Protection (SMPS load) | Air switch | |||||||||
Output Short Circuit Protection | Air switch | |||||||||
Max Bypass Overload Current | 40A/50A/80A | |||||||||
Battery Invert Mode Specifications: |
||||||||||
AC output | Output Voltage Waveform | Sine wave | ||||||||
Rated Output Power (KW) | LV:4KW/5KW/6KW | HV: 4KW/5KW/ 6KW/7KW/8KW/10KW |
||||||||
Power Factor | 0.9~1.0 | |||||||||
Nominal Output Voltage (V) | LV:120Vac ±10%rms | HV:230Vac ±10%rms | ||||||||
Nominal Output Frequency (Hz) | 60Hz ± 0.3Hz 50Hz ± 0.3Hz |
|||||||||
DC Voltage | Nominal DC Input Voltage | 24VDC/48VDC | ||||||||
DC Voltage range | 20-31.0Vdc for 24VDC 40-62.0Vdc for 48VDC |
|||||||||
Low Battery Alarm | 21.0Vdc ± 0.6Vdc for 24V battery 42.0Vdc ± 1.2Vdc for 48V battery |
|||||||||
Low DC input Shut-down | 20.0vdc± 0.6Vdc for 24V battery 40.0Vdc ± 1.2Vdc for 48V battery |
|||||||||
High DC input Alarm & Fault | 32Vdc ± 0.6Vdc for 24V battery 64Vdc ± 1.2Vdc for 48V battery |
|||||||||
High DC input Recovery | 31.0Vdc ± 0.6Vdc for 24V battery 62.0Vdc ± 1.2Vdc for 48V battery |
|||||||||
AC Charger | Nominal Charge Current | 35A/50A/70A (5 stages adjustable charging current) | ||||||||
Charge Current Regulation | ± 5Adc | |||||||||
Over Charge Protection | Bat.V≥31.0VDC for 24V battery Bat.V≥62.0VDC for 48V battery beeps 0.5s every 1s & fault after 60s |
|||||||||
Algorithm | Three stage: Boost CC (constant current stage) → Boost CV (constant voltage stage) → Float (constant voltage stage) | |||||||||
Solar charger | Rated Charge Current | 40A | 60A | |||||||
Rated charge battery Voltage type | 24V/48V | 24V | ||||||||
Max.PV open circuit array voltage | 24V for 55Vdc 48V for 110Vdc |
|||||||||
Charger mode | MPPT | |||||||||
PV Low Voltage Re-connect | PV≥Bat.V=3V | |||||||||
PV Low Voltage Disconnect | PV<=Bat.V | |||||||||
Efficiency | ≥97% | |||||||||
Efficiency | Efficiency (Battery Mode) | ≥85% | ||||||||
Efficiency (Line Mode) | >98% | |||||||||
Transfer Time | Ac to Dc | 20ms (Max) | ||||||||
Dc to Ac | 15ms (Max) | |||||||||
System parameter | Over-Load Protection | 110% <load<150%, beeps 0.5s every 1s, and Fault after 60s off the output, Load>150%, beeps 0.5s every 1s, and Fault after 20s. | ||||||||
Output Short Circuit Protection | Current limit (Fault after 10s) | |||||||||
Surge rating (10s) | 1:3 (VA) | |||||||||
Power saver | Load <=25W (Enabled on "P/S auto" setting of Remote control) | |||||||||
Protections | Low battery, over charging, over load , over temp. | |||||||||
Indicators | LED+LCD Display | |||||||||
General Specifications | Operating Temperature Range | 0°C to 40°C | ||||||||
Storage temperature | -15ºC ~60ºC | |||||||||
Operation humidity | 5% to 95%(non-condensing) | |||||||||
Audible Noise | 60dB max | |||||||||
Cooling | Forced air, variable speed fan | |||||||||
Dimension(L*W*H) | 4KW | 5KW | 6KW | 7KW | 8KW | 10KW | ||||
530*400*190mm | 590*420*195mm | |||||||||
Net weight(Kg) | 30.0 | 35.5 | 38.5 | 41.5 | 48.0 | 55.0 |
MODEL (GW Series) |
HV/LV Model | ||||||||
HV Model(1-12KW) LV Model(1-6KW) | |||||||||
Line Mode Specifications: |
|||||||||
Input Voltage | Input Voltage Waveform | Sinusoidal (utility or generator) | |||||||
Nominal Input Voltage | LV 120Vac | HV 230Vac | |||||||
Low Line Disconnect | Normal:85Vac±4% Wide:80Vac±4% | Normal:184Vac±4% Wide:135Vac±4% | |||||||
Low Line Re-connect | Normal:95Vac±4% Wide:85Vac±4% | Normal:194Vac±4% Wide:145Vac±4% | |||||||
High Line Disconnect | Normal:136Vac±4% Wide:140Vac±4% | Normal:263Vac±4% Wide:263Vac±4% | |||||||
High Line Re-connect | Normal:131Vac±4% Wide:135Vac±4% | Normal:253Vac±4% Wide:253Vac±4% | |||||||
Max AC Input Voltage | 150Vrms | 270Vrms | |||||||
Input Frequency | Nominal Input Frequency | 50Hz/ 60Hz (Auto detection) | |||||||
Low Line Frequency Re-connect | 51+0.3Hz for 60Hz; 41+0.3Hz for 50Hz; |
||||||||
Low Line Frequency Disconnect | 50+0.3Hz for 60Hz; 40+0.3Hz for 50Hz; |
||||||||
High Line Frequency Re-connect | 64+0.3Hz for 60Hz; 54+0.3Hz for 50Hz; |
||||||||
High Line Frequency Disconnect | 65+0.3Hz for 60Hz; 55+0.3Hz for 50Hz; |
||||||||
main functions | Output Voltage Waveform | As same as Input Waveform | |||||||
Over-Load Protection (SMPS load) | Air switch | ||||||||
Output Short Circuit Protection | Air switch | ||||||||
Max Bypass Overload Current | 30A/40A/50A | ||||||||
Battery Invert Mode Specifications: |
|||||||||
output | Output Voltage Waveform | Sine wave | |||||||
Rated Output Power (KW) | LV:1~6KW | HV: 1~12KW | |||||||
Power Factor | 0.9~1.0 | ||||||||
Nominal Output Voltage (V) | LV:120Vac ±10%rms | HV:230Vac ±10%rms | |||||||
Nominal Output Frequency (Hz) | 60Hz ± 0.3Hz 50Hz ± 0.3Hz |
||||||||
DC Voltage | Nominal DC Input Voltage | 12VDC/24VDC/48VDC | |||||||
DC Voltage range | 10-15.5Vdc for 12VDC 20-31.0Vdc for 24VDC 40-62.0Vdc for 48VDC |
||||||||
Low Battery Alarm | 10.5Vdc ± 0.3Vdc for 12V battery 21.0Vdc ± 0.6Vdc for 24V battery 42.0Vdc ± 1.2Vdc for 48V battery |
||||||||
Low DC input Shut-down | 10.0Vdc ± 0.3Vdc for 12V battery 20.0vdc± 0.6Vdc for 24V battery 40.0Vdc ± 1.2Vdc for 48V battery |
||||||||
High DC input Alarm & Fault | 16Vdc ± 0.3Vdc for 12V battery 32Vdc ± 0.6Vdc for 24V battery 64Vdc ± 1.2Vdc for 48V battery |
||||||||
High DC input Recovery | 15.5Vdc ± 0.3Vdc for 12V battery 31.0Vdc ± 0.6Vdc for 24V battery 62.0Vdc ± 1.2Vdc for 48V battery |
||||||||
AC Charger | Nominal Charge Current | 20A/35A/50A/70A/90A(5 stages adjustable charging current) | |||||||
Charge Current Regulation | ± 5Adc | ||||||||
Over Charge Protection | Bat.V≥15.5VDC for 12V battery Bat.V≥31.0VDC for 24V battery Bat.V≥62.0VDC for 48V battery beeps 0.5s every 1s & fault after 60s |
||||||||
Algorithm | Three stage: Boost CC (constant current stage) → Boost CV (constant voltage stage) → Float (constant voltage stage) | ||||||||
Solar charger | Rated Charge Current | 40A | 60A | ||||||
Rated charge battery Voltage type | 12V/24V/48V | 12V/24V | |||||||
Max.PV open circuit array voltage | 12V for 40Vdc 24V for 55Vdc 48V for 110Vdc |
||||||||
Charger mode | MPPT | ||||||||
PV Low Voltage Re-connect | PV≥Bat.V=3V | ||||||||
PV Low Voltage Disconnect | PV<=Bat.V | ||||||||
Efficiency | ≥97% | ||||||||
Efficiency | Efficiency (Battery Mode) | ≥85% | |||||||
Efficiency (Line Mode) | >98% | ||||||||
Transfer Time | Ac to Dc | 20ms (Max) | |||||||
Dc to Ac | 15ms (Max) | ||||||||
System parameter | Over-Load Protection | 110% <load<150%, beeps 0.5s every 1s, and Fault after 60s off the output, Load>150%, beeps 0.5s every 1s, and Fault after 20s. | |||||||
Output Short Circuit Protection | Current limit (Fault after 10s) | ||||||||
Surge rating (10s) | 1:3 (VA) | ||||||||
Power saver | Load <=25W (Enabled on "P/S auto" setting of Remote control) | ||||||||
Protections | Low battery, over charging, over load , over temp. | ||||||||
Indicators | LED+LCD Display | ||||||||
General Specifications | Operating Temperature Range | 0°C to 40°C | |||||||
Storage temperature | -15ºC ~60ºC | ||||||||
Operation humidity | 5% to 95%(non-condensing) | ||||||||
Audible Noise | 60dB max | ||||||||
Cooling | Forced air, variable speed fan | ||||||||
Dimension(L*W*H) | 3KW | 5KW | 6KW | 8KW | 10KW | 12KW | |||
Net weight(Kg) |