Customization: | Available |
---|---|
Application: | Charger Controller |
Weitght: | 2.0kg |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL | Solar charge controller-40A | |
Rated Voltage | 12/24VDC | |
Rated charge current | 40A | |
Load current | 15A | |
Input voltage rang | 15-55VDC | |
Max.PV open circuit array voltage |
55VD | |
Typical idle consumption | <10mA | |
Overload protection (DC load) |
2.0×inom>5s 1.5×inom>20s 1.25×inom temperature controlled |
|
Bulk charge | 14.6V(default) | 29.2V(default) |
Floating charge | 13.4V (default) | 26.8V (default) |
Equalization charge | 14.0V (default) | 28.0V (default) |
Over charge disconnection | 14.8V | 29.6V |
Over charge recovery | 13.6V | 27.2V |
Over discharge disconnection | 10.8V(default) | 21.6V(default) |
Over discharge reconnection | 12.3V | 24.6V |
Temperature compensation | -13.2mv/c | -26.4mv/c |
Lead acid battery setting | Adjustable | |
Nicad battery setting | Adjustable | |
Load control mode |
1. Low Voltage Reconnect (LVR): Adjustable 2. Low Voltage Disconnect (LVR): Automatic Disconnection 3.Reconnection:Includes warning flash before disconnect and reconnect |
|
Low voltage reconnect | 12.0-14.0Vdc | 24.0-28.0Vdc |
Low voltage disconnect | 10.5-12.5Vdc | 21.0-25.0Vdc |
Ambient temperature | 0-40c(full load)40-0c(de-rating) | |
Altitude | Operating 5000m,Non-operating 16000m | |
Protection class | IP21 | |
Batterytemperature sensor | BTS optional remote batter temperature sensor for increased charging precision |