Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 24months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL
|
LW-1000
|
LW-1500
|
LW-2000
|
LW-3000
|
LW-4000
|
LW-5000
|
LW-6000
|
||||
Nominal Power
|
1000W
|
1500W
|
2000W
|
3000W
|
4000W
|
5000W
|
6000W
|
||||
AC Input
|
|||||||||||
Phase &
waveform
|
Single phase & Pure Sine Wave
|
||||||||||
Voltage
|
110/120/130VAC or 220/230/240VAC
|
||||||||||
Acceptable Voltage
|
95-126VAC or 194-253VAC±4%
|
||||||||||
Low Line Disconnect
|
85VAC±4% or 184VAC±4%
|
||||||||||
Low Line Re-connect
|
95VAC±4% or 194VAC±4%
|
||||||||||
High Line Disconnect
|
136VAC±4% or 263VAC±4%
|
||||||||||
High Line Re-connect
|
126VAC±4% or 253VAC±4%
|
||||||||||
Frequency
|
50Hz:41-54Hz 60Hz:51-64Hz
|
||||||||||
AC Output
|
|||||||||||
Phase & waveform
|
Single phase & Pure Sine Wave (bypass mode sync to input)
|
||||||||||
Voltage
|
110/120/130VAC or 220/230/240VAC±10%rms (bypass mode sync to input)
|
||||||||||
Frequency
|
50Hz±0.3Hz 60Hz±0.3Hz (bypass mode sync to input)
|
||||||||||
Peak Power
|
3 times of rating power
|
||||||||||
Short Circuit
Protection
|
Yes, shutdown after 10ms
|
||||||||||
Power Factor
|
0.9-1.0
|
||||||||||
DC Input
|
|||||||||||
Battery Voltage
|
12VDC or 24VDC or 48VDC
|
||||||||||
Minimum Start
Voltage
|
10VDC or 20VDC or 40VDC
|
||||||||||
Low Battery Alarm
|
10.5±0.3vdc or 21±0.6vdc or 42±1.2vdc
|
||||||||||
Low DC input
Shut-down
|
10±0.3vdc or 20±0.6vdc or 40±1.2vdc
|
||||||||||
High DC input Alarm & Fault
|
16±0.3vdc or 32±0.6vdc or 64±1.2vdc
|
||||||||||
High DC input
Recovery
|
15.5±0.3vdc or 31±0.6vdc or 62±1.2vdc
|
||||||||||
MAX Charger
Current
|
20A/35A/ 50A/75A/90A(According to the Inverter model)
|
||||||||||
System parameter
|
|||||||||||
Battery Mode
Efficiency
|
>85%
|
||||||||||
Line Mode
Efficiency
|
>96%
|
||||||||||
power saver
|
Load <=25W (Enabled on "P/S auto" setting of Remote control)
|
||||||||||
Audible Alarm
|
Sounding when the heat sink's tem is over 100ºC and shutdown after 30 seconds.
|
||||||||||
Over Load
Protection
|
110% <LOAD<150%, FONT 60s.< after Fault and 1s, every 0.5s beeps>
Load>150%, beeps 0.5s every 1s, and Fault after 20s.
|
||||||||||
Protections
|
low battery,over charging,over temp,over load
|
||||||||||
Communications
|
RS-232/USB/SNMP(custom-made)
|
||||||||||
Operating Environment
|
0-40ºC,0-90%RH(non-condensing)
|
||||||||||
Audible Noise
|
<60dB
|
||||||||||
Net Weight(KG)
|
16kg
|
18kg
|
20kg
|
25kg
|
39kg
|
42kg
|
49kg
|
||||
Dimension L X W X H
|
470 X223 X185mm
|
650 X223 X185mm
|