| Customization: | Available |
|---|---|
| After-sales Service: | Yes |
| Warranty: | 24-Month |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Model Parameters | GS1000 | GS2000 | GS3000 | GS4000 | GS5000 | GS6000 | GS8K | GS10K | GS12K | |
| AC Input | Nominal Power | 1000W | 2000W | 3000W | 4000W | 5000W | 6000W | 8KW | 10KW | 12KW |
| Input Voltage Waveform | sinusoidal(utility or generator) | |||||||||
| Nominal input Voltage | HOT1-HOT2: 240VAC | |||||||||
| Low Line Disconnect | 180Vac±4%(Normal) or 140Vac±4%(Wide) | |||||||||
| Low Line Re-connect | 190Vac±4%(Normal) or 150Vac±4%(Wide) | |||||||||
| High Line Disconnect | 270Vac±4%(Normal) or 270Vac±4%(Wide) | |||||||||
| High Line Re-connect | 260Vac±4%(Normal) or 260Vac±4%(Wide) | |||||||||
| Max AC input Voltage | Max280V | |||||||||
| Frequency | 50Hz:41-54Hz, 60Hz:51-64Hz | |||||||||
| AC Output | Output Voltage Waveform | Sine wave | ||||||||
| Power Factor | 1.0 | |||||||||
| Nominal Output Voltage (V) | HOT1-N: 120Vac ±10%rms; HOT2-N: 120Vac ±10%rms; HO1-HOT2: 240Vac ±10%rms |
|||||||||
| output phase diifference | HOT1-N and HOT2-N is 180°; HOT1-N and HOT1-HOT2 is 0°; HOT2-N and HOT1-HOT2 is 180° |
|||||||||
| Nominal Output Frequency (Hz) |
50Hz ± 1Hz, 60Hz ± 1Hz | |||||||||
| AC Charger | Nominal Charger Current |
20A/35A/50A/70A/90A(According to the inverter model) ; adjustable 5 stages charging current; |
||||||||
| Over charge Protection | Bat.V≥15.5VDC for 12V battery, Bat.V≥31.0VDC for 24V battery ,Bat.V≥62.0VDC for 48V battery; beeps 0.5s every 1s & fault after 60s | |||||||||
| Solar charger |
Rated Charge Current | alternative 40A/60A | ||||||||
| PV Input Voltage range | 15VDC-40VDC for 12VDC, 30VDC-75VDC for 24VDC, 60-145VDC for 48V | |||||||||
| Max.PV open circuit array voltage |
12V for 40Vdc, 24V for 75Vdc, 48V for 145Vdc | |||||||||
| Charger mode | MPPT | |||||||||
| PV Low Voltage Re-connect |
PV≥Bat.V+3V | |||||||||
| PV Low Voltage Disconnect |
PV<=Bat.V | |||||||||
| Efficiency | ≥97% | |||||||||
| Battery Voltage | Nominal DC input Voltage | 12/24/48VDC | 24/48VDC | 48VDC | ||||||
| Low Battery Alarm | 10.5VDC±0.3VDC for 12VDC | |||||||||
| 21VDC±0.6VDC for 24VDC | ||||||||||
| 42VDC±1.2VDC for 48VDC | ||||||||||
| Low DC input shut & down |
10VDC±0.3VDC for 12VDC | |||||||||
| 20VDC±0.6VDC for 24VDC | ||||||||||
| 40VDC±1.2VDC for 48VDC | ||||||||||
| High DC input Alarm & Fault |
16VDC±0.3VDC for 12VDC | |||||||||
| 32VDC±0.6VDC for 24VDC | ||||||||||
| 64VDC±1.2VDC for 48VDC | ||||||||||
| Efficiency | Efficiency(Battery Mode) | ≥87% | ||||||||
| Efficiency (Line Mode) | >98% | |||||||||
| Transfer Time | AC tO DC | 20ms(max) | ||||||||
| DC tO AC | 15ms(max) | |||||||||
| System Parameter | Over-Load Protection | 110%<load<150%, beeps 0.5s every 1s, and Fault after 60s off the output,load>150%, beeps 0.5s every 1s, and Fault after 20s |
||||||||
| Output Short Circuit Protection |
YES | |||||||||
| Surge Rating | 1:3(VA) | |||||||||
| Protections | Low battery, over charging, over load, over temp | |||||||||
| Indicators | LED+LCD Display | |||||||||
| General Specifications |
Operating Temperature Range |
0ºC~40ºC | ||||||||
| Storage Temperature | -15ºC~60ºC | |||||||||
| Operation humidity | 5% to 95%(non-condensing) | |||||||||
| Audible Noise | 60dB max | 80dB max | ||||||||
| cooling | Forced air,variable speed fan | |||||||||
| Dimension(L*W*H) | 480*336*190mm | 530*400*190mm | 627*416*204mm | |||||||
| Net Weight(kg) | 19.5kg | 23.5kg | 30kg | 30kg | 35.5kg | 39kg | 52.5kg | 58.5kg | 66.5kg | |