Customization: | Available |
---|---|
Nature of Source Flow: | Passive inverter |
Certification: | ISO9001, CE |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model Parameters | HD500-12 | HD1000S-12 | HD1000-12 | HD2000-24 | |
AC Input |
Nominal Power | 330W | 660W | 800W | 1440W/1500W/1600w |
Input Voltage Waveform | Sinusoidal (utility or generator) | ||||
Nominal input Voltage | 230VAC | ||||
Selectable Voltage Range | 165-270Vac±4%(Narrow Range), 85-270Vac±4%(Wide Range) | ||||
Max AC input Voltage | Max:270VAC | ||||
Frequency | 50Hz:or 60Hz | ||||
AC output |
Output Voltage Waveform | Modified sine wave | |||
Voltage Regulation (Batt.Mode) | 230VAC (+10% / -18%) | ||||
Nominal Output Frequency (Hz) |
50Hz or 60Hz (Auto detection) | ||||
Transfer Time | 15ms Typical, 20ms Max. | ||||
AC Charger |
Charging Algorithma | 3-step charging | |||
Nominal Charger Current | 15 Amp or 20Amp Selectable | 10Amp | |||
Floating Charging Voltage | 13.7VDC | 27.4VDC | |||
Over charge Protection | 16VDC | 32VDC | |||
Efficiency | Efficiency (Battery Mode) | >80% | |||
Efficiency (Line Mode) | >95% | ||||
Battery Voltage |
Nominal DC input Voltage | 12VDC | 24VDC | ||
Low Battery Alarm | 10.5VDC±0.3VDC | 21VDC±0.6VDC | |||
Low DC input shut-down | 10VDC±0.3VDC | 20VDC±0.6VDC | |||
High DC input Alarm & Fault |
16VDC±0.3VDC | 32VDC±0.6VDC | |||
System Parameter |
Protections | Low battery, over charging, over load, over temp | |||
Indicators | LCD+LED Display | ||||
Over-Load Protection | 1min Load >110%,20s Load >120%,0s Load >150% | ||||
General Specifications |
Operating Temperature Range |
0ºC to 40ºC | |||
Storage Temperature | -15ºC~55ºC | ||||
cooling | Forced air,variable speed fan | ||||
Dimension(L*W*H) | 276.7*245*97mm | ||||
Net Weight(kg) | 1.8 | 2.1 | 2.2 | 2.6 | |
Product specifications are subject to change without further notice |