10kVA-400kVA 3phase Low frequency Online UPS, DSP Control, Isolation Transformer, SNMP remote control
Detailed Product Description
384VDC battery voltage input
Isolation transformer
Low frequency 3phase Online UPS
SNMP Remote control Interne
380/400/415VA
Low frequency 3phase Online UPS, Uninterruptible power supply, from 10kVA-400kVA.
They are online UPS with isolation transformer, can control on Internet through SNMP software.
It is used in large IDC rooms, banks/securities settlement centers, communication network management centers, semiconductor product lines and large automation production and its control system.
According to the special needs of users the low frequency online UPS was improved, and is used in large sports venues, conference rooms, theaters and highway and railway tunnels metal halide lamp lighting systems.
Functions:
GP33 series Low frequency Online UPS is most advanced and new intelligent digital UPS by
. It is combined with high speed MCU, advanced CPLD technology, the sixth generation low consume large
, IGBT and static switch.
Products features:
1. Intelligent inspect and monitor UPS systems every second
2. The sixth generation IGBT inverter technology
3. High definition touch screen LCD display and LED indicators, can show directly UPS status and operation, data records in table format, and events records.
4. Adopts knock-down modular design, easy to maintain and save resources much; It is with new advanced turbofan which can release heat well and save energy; It also use non-circumfluence controlled circuit, can save electric much; GP33 UPS adopts green commute and inverter technology, ensure to provide clear energy for users; Its advanced digital circuit technology let whole UPS with 80% more life than before.
5. Excellent load characters can fulfill with suddenly change load from 0 to 100%, and no need to invert to bypass, ensure output stable and reliable.
6. Well-equipped protection function, including alarm function and excellent input and output under voltage overflow protection, input surge protection, phase failure protection, battery overcharge and over discharge protection, output overload short circuit protection, over heat protection and so on.
7. Three phase can equal stable voltage and control separately, in order to control instantaneous overload degree of equal, realize output imbalance 100% load.
8. Optional input harmonic filter or Twelve-pulse rectifier can restrain input harmonic pollution efficiently, improve UPS input power factor, and minish input harmonic current.
9. Optional battery inspection module, can test specification of every battery, and show on display. If battery faulty, will alarm immediately and inform administrators.
10. Special set: Can set UPS work status according to requirements of electric. User can choose from UPS operate mode, ECO save energy operate mode and EPS operate mode.
Model |
GP5310 ~ GP53200 series UPS |
|
Capacity(VA) |
10K |
15K |
20K |
30K |
40K |
60K |
80K |
100K |
120K |
160K |
200K |
Noninal output capacity |
8KW |
12KW |
16KW |
24KW |
32KW |
48KW |
64KW |
80KW |
96KW |
128KW |
160KW |
Operate type |
Double conversion online type |
|
Input |
voltage |
220V/380,230/400,240/415V,±25% |
|
Phase |
Three phase +N+G |
|
Frequency |
50Hz/60Hz±5% |
|
Input power factor |
0.95(with input filter) |
|
Soft start |
0-100% 5sec |
|
Output |
Voltage |
220V/380,230/400,240/415V,±1% (stable load) ,±5%(active load) |
|
Phase |
Three phase +N+G |
|
Frequency |
50/60Hz (1±5%,AC mode),50/60Hz (±1%,Battery mode) |
|
Power factor |
0.8 |
|
Output wave |
Pure sine wave |
|
Distortion |
Linear load <3%, non linear load<5% |
|
Batteryvoltage |
Standard battery voltage |
360V/384V |
|
Floating charge |
405V/432V |
|
Terminal voltage |
315V/336V |
|
Charge current |
1A-50A (Can calculate and set according to battery configuration software) |
|
Maximum discharge current |
28 |
42 |
56 |
85 |
113 |
169 |
225 |
282 |
338 |
381 |
507 |
Main Function |
Active voltage change |
0-100%±5% |
|
Instant recover time |
<10ms |
|
Imbalance voltage |
<±5%,<±1%( Balance load voltage) |
|
Overload capacity |
125%→10min,150%→1min |
|
Static switch |
Automatic |
|
Protection |
UPS over current, short circuit, battery low voltage, over heat |
|
Cold method |
Compel aeration ( temperature control mode) |
|
Noise |
60-65dB |
|
Display |
LED,LCD display |
|
Communicatin port(Optional) |
RS232,SNMP,dry-contact |
|
Alarm |
Alarm with buzzer and indicators |
|
Environment |
Temperature 0~40cHumidity 0~90% |
|
GP 33 series three phase online ups can configure battery according to customers'needed back up time
OEM/ODM service also avaiable
AGM lead acid battery,GEL battery ,deep cycle battery optional
Delivery time:7~15 working days after payment received
24 months warranty