| Customization: | Available |
|---|---|
| Nature of Source Flow: | Active Inverter |
| Phase: | Single |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
All kinds of home applicance,office equipment,solar power system,and other equipments which use single phase power
1.PW Pure sine wave charger inverter 8-12KW.
2.LED/LCD display, enhanced funvtions setting via LCD, Man-machine intelligent design.
3.5 stages adjustable AC charging current.AC charging also can be closed.
4.AC/DC priority modes can be set.
5.RS-232,Generator restart signal.(Dry contact).
6.3 times peak power.Strong loading capacity.
7.Overload,output short-circuit protection.
| PRODUCT DETAIL |
| MODEL (PW Series) |
HV Model | |||
| PW8-12KW HV(230Vac) | ||||
| Line Mode Specifications: | ||||
| Input Voltage | Input Voltage Waveform | Sinusoidal (utility or generator) | ||
| Nominal Input Voltage | 230Vac | |||
| Low Line Disconnect | 184Vac±4% | |||
| Low Line Re-connect | 194Vac ±4% | |||
| High Line Disconnect | 263Vac±4% | |||
| High Line Re-connect | 253Vac±4% | |||
| Max AC Input Voltage | 270Vrms | |||
| Input Frequency | Nominal Input Frequency | 50Hz/ 60Hz (Auto detection) | ||
| Low Line Frequency Re-connect | 51+0.3Hz for 60Hz; 41+0.3Hz for 50Hz; |
|||
| Low Line Frequency Disconnect | 50+0.3Hz for 60Hz; 40+0.3Hz for 50Hz; |
|||
| High Line Frequency Re-connect | 64+0.3Hz for 60Hz; 54+0.3Hz for 50Hz; |
|||
| High Line Frequency Disconnect | 65+0.3Hz for 60Hz; 55+0.3Hz for 50Hz; |
|||
| main functions |
Output Voltage Waveform | As same as Input Waveform | ||
| Over-Load Protection (SMPS load) | Fuse | |||
| Output Short Circuit Protection | Fuse | |||
| Transfer Switch Rating | 63A/80A/100A | |||
| Max Bypass Overload Current | 100A | |||
| Battery Invert Mode Specifications: | ||||
| output | Output Voltage Waveform | Sine wave | ||
| Rated Output Power (KW) | 8kw/10kw/12kw | |||
| Power Factor | 0.9~1.0 | |||
| Nominal Output Voltage (V) | 230Vac ±10% rms | |||
| Nominal Output Frequency (Hz) | 60Hz ± 0.3Hz 50Hz ± 0.3Hz |
|||
| DC Voltage | Nominal DC Input Voltage | 48V/72V | ||
| DC Voltage range | 40-62Vdc for 48VDC/ 70-93Vdc for 72VDC | |||
| Low Battery Alarm | 42.0Vdc ± 1.2Vdc for 48V battery 63.0Vdc ± 1.8Vdc for 72V battery |
|||
| Low DC input Shut-down | 40.0Vdc ± 1.2Vdc for 48V battery 60.0vdc± 1.8Vdc for 72V battery |
|||
| High DC input Alarm & Fault | 64Vdc ± 1.2Vdc for 48V battery 96Vdc ± 1.8Vdc for 72V battery |
|||
| High DC input Recovery | 62.0Vdc ± 1.2Vdc for 48V battery 93.0Vdc ± 1.8Vdc for 72V battery |
|||
| Charger | Nominal Charge Current | 35A/50A(5 stages adjustable charging current) | ||
| Charge Current Regulation | ± 5Adc | |||
| Over Charge Protection | Bat. V ≥62Vdc / 93Vdc, beeps 0.5s every 1s & fault after 60s | |||
| Algorithm | Three stage: Boost CC (constant current stage) → Boost CV (constant voltage stage) → Float (constant voltage stage) | |||
| Efficiency | Efficiency (Battery Mode) | ≥85% | ||
| Efficiency (Line Mode) | >98% | |||
| Transfer Time | Ac to Dc | 20ms (Max) | ||
| Dc to Ac | 15ms (Max) | |||
| System parameter | Over-Load Protection | 110% <load<150%, beeps 0.5s every 1s, and Fault after 60s off the output, Load>150%, beeps 0.5s every 1s, and Fault after 20s. | ||
| Output Short Circuit Protection | Current limit (Fault after 10s) | |||
| Surge rating (10s) | 1:3 (VA) | |||
| Power saver | Load <=25W (Enabled on "P/S auto" setting of Remote control) | |||
| Protections | Low battery, over charging, over load , over temp. | |||
| Indicators | LED+LCD Display | |||
| General Specifications | Operating Temperature Range | 0°C to 40°C | ||
| Storage temperature | -15ºC ~60ºC | |||
| Operation humidity | 5% to 95%(non-condensing) | |||
| Audible Noise | 60dB max | |||
| Cooling | Forced air, variable speed fan | |||
| Dimension(L*W*H) | 538*255*630mm | |||
| Net weight(Kg) | 8KW | 10KW | 12KW | |
| 60kg | 65.5kg | 71kg | ||
Detailed pictures