Application: | Home Theater |
---|---|
Nature of Source Flow: | Passive inverter |
Certification: | ISO9001, CE |
Output Power: | >1000W |
Brand: | Zlpower |
Grid Type: | off-Grid Inverter |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Mode No. : | LW1000,LW2000,LW3000,LW5000,LW6000 |
Classification: | Low frequency Inverter |
Introduction: | Based on transformer technology,strong loading capacity.Used for all kinds of home/office equipments,solar power system. |
Model |
LW1000 |
LW2000 |
LW3000 |
LW4000 |
LW5000 |
LW6000 |
|
AC Input |
Nominal Power | 1000W |
2000W |
3000W |
4000W |
5000W |
6000W |
Voltage | 120VAC/230VAC |
230VAC |
|||||
Acceptable Voltage | 194-243VAC/164-243VAC(wide mode) |
||||||
Line low Transfer | 85V±4%/184(154 wide mode±4% ) |
||||||
Line low Return | 95V±4%/194(164 wide mode±4% ) |
||||||
Line high Transfer | 135V±4%/253±4% |
||||||
Line high Return | 127V±4%/243±4% |
||||||
Frequency | 50Hz or 60Hz (auto sensing) |
||||||
Line low Transfer | 47Hz for 50Hz, 57Hz for 60 Hz |
||||||
Line high Transfer | 55Hz for 50Hz, 65Hz for 60 Hz |
||||||
Out Input |
Phase &waveform | Pure Sine Wave(bypass mode sync to input) |
|||||
Voltage | 100/110/120/130VAC, 208/220/230/240VAC (bypass mode sync to input) |
||||||
Voltage Regulation | ±10%rms(bypass mode sync to input) |
||||||
Frequency | 50Hz±0.3Hz(bypass mode sync to input) |
||||||
Peak Power | 3 times of rating power |
||||||
Short Circuit Protection | Yes, shutdown after 10ms |
||||||
Power Factor | 0.9-1.0 |
||||||
DC Input |
Battery Voltage | 12V/24V/48V |
24V/48V |
||||
Minimum Start Voltage | 10V for 12V, 20V for 24V, 40V for 48V |
||||||
Low Battery Alarm | 10.5V for 12V, 21V for 24V, 42V for 48V |
||||||
Low Battery Transfer | 10V for 12V, 20V for 24V, 40V for 48V |
||||||
High Voltage Alarm | 16V for 12V, 32V for 24V,64V for 48V |
||||||
Max Charging Current | 20A/35A/70A/90A |
||||||
Over charge Voltage | 15.7V for 12V,31.4V for 24V, 62.8V for 48V |
||||||
Transfer Efficiency |
Line Mode | >95% |
|||||
Battery Mode | >88% |
||||||
Power saver | Available when the load is less than 25 Watts |
||||||
Indicators |
Switch selector | Saving Mode is on/off when push the switch forwards/backwards , |
|||||
Audible Alarm | Sounding when the heatsink's tem is over 105ºC and shutdown after 30 seconds. |
||||||
Protections | low battery/ over charging /over temp/over load |
||||||
Communications | RS-232/USB(custom-made) |
||||||
Enviromental |
Operating Environment | 0-40ºC,0-90%ºC RH(non-condensing) |
|||||
Audible Noise | <60dB |
||||||
Net Weight (KG) | 18 |
20 |
22 |
35 |
38 |
40 |
|
Dimension(LxWxH) | 446×218×179mm |
605×218×179mm |
Suppliers with verified business licenses