Customization: | Available |
---|---|
Nature of Source Flow: | Active Inverter |
Phase: | Single |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model |
PSC Plus3K-24 |
PSC Plus5K-48 |
|
AC |
Nominal Power |
3KVA/2400W |
5KVA/4200W |
Input Voltage Waveform |
Sinusoidal (utility or generator) |
||
Nominal input Voltage |
230VAC |
||
Low Line Disconnect |
170Vac±4%(Normal) or 90Vac±4% (Wide&Gen) |
175Vac±4%(Normal) or 125Vac±4%(Wide&Gen) |
|
High Line Disconnect |
280Vac±4%(Normal) or 280Vac±4%(Wide&Gen) |
280Vac±4%(Normal) or 280Vac±4%(Wide&Gen) |
|
Max AC input Voltage |
Max:300VAC |
||
Frequency |
50Hz/60Hz(Auto detection) |
||
AC |
Output Voltage Waveform |
Sine wave |
|
Power Factor |
0.8 |
0.84 |
|
Bypass Breaker Size |
30A |
40A |
|
Nominal Output Frequency (Hz) |
50Hz / 60Hz ± 1Hz |
||
Capable of starting electric motor |
1.5HP |
2.5HP |
|
Full load efficiency |
90% |
||
Solar |
Charger mode |
MPPT |
|
Maximun PV Array Power |
960W |
2800W |
|
Rated Charge Current |
40A |
60A |
|
PV Low Voltage Disconnect |
25VDC±0.6VDC |
50VDC±1.2VDC |
|
PV High Voltage disconnect |
75VDC±0.6VDC |
150VDC±1.2VDC |
|
Efficiency |
≥98% |
||
AC |
Nominal Charger Current |
20A @170Vac~280Vac; 10A @90Vac~170Vac |
25A @180Vac~280Vac; 20A @125Vac~180Vac |
Over charge Protection |
30VDC±0.6VDC |
60VDC±1.2VDC |
|
Floating Charge Voltage |
27.4VDC±0.6VDC |
54.8VDC |
|
Battery |
Nominal DC input Voltage |
24VDC |
48VDC |
Low Battery Alarm |
21VDC±0.6VDC |
42VDC±1.2VDC |
|
High DC input Alarm & Fault |
29VDC±0.6VDC |
58VDC±1.2VDC |
|
Transfer Time |
Normal range : 10ms (typical) 15ms (max) |
||
System |
Over-Load Protection |
110%the output,load≥150%,beeps 0.5s every 1s,and Fault after 5s |
|
Output Short Circuit Protection |
Current limit (Fault after 4 cycles max) |
||
Surge Rating |
1:2(VA) |
||
Protections |
Low battery, over charging, over load, over temp |
||
General |
Operating Temperature Range |
0ºC to 40ºC |
|
Storage Temperature |
-15ºC~60ºC |
||
Operation Humidity |
5% to 95%(non-condensing) |
||
Audible Noise |
60dB max |
||
cooling |
Forced air,variable speed fan |
||
Dimension(L*W*H) |
326*268*88.8mm |
456*356.8*118mm | |
Net Weight(kg) |
5.6 |
11.1 |
MODEL |
PSC 3KVA-24 |
PSC 6KVA-48 |
PSC 6KVA-96 |
|
Rated Output Power |
3000VA/2400W |
6000VA/4200W(4800W) |
6000VA/4200W(4800W) |
|
PF |
0.8 |
0.7/0.8 |
0.7/0.8 |
|
Surge Rating |
4800W |
8400W |
8400W |
|
Capable of starting electric motor |
1.5HP |
2.5HP |
2.5HP | |
Nominal Input Voltage |
220/230/240vac |
|||
Nominal Input Voltage |
24vdc |
48vdc |
96vdc |
|
Output Voltage |
220/230/240Vac ±10% rms |
|||
Nominal Efficiency |
>90% (@Normal DC Input; >60% R load) |
|||
Output Frequency |
50Hz / 60Hz ± 1Hz (follow first connect to grid) |
|||
Over-Load Protection |
fault after 5s@≥150% load,<=200% load fault after 10s@110%~150% load |
|||
Nominal Charge Current |
10A @Vi/p<170Vac 20A@Vi/p=230Vac 10A @Vi/p>280Vac |
20A(95-175v, gen/wide only), 35A(175-275v)@35A setting 20A(175v-275v)@20A setting) |
10A(95-175v, gen/wide only), 20A(175-275v)@20A setting 10A(175v-275v)@10A setting) |
|
Output waveform |
Pure Sine Wave |
|||
Charge Voltage |
27vdc |
54vdc |
108vdc |
|
Over Charge Protection |
Bat. V ≥30Vdc, Fault, Buzzer alarm |
Bat. V≥60Vdc, Fault, Buzzer alarm |
Bat. V ≥120Vdc,Fault, Buzzer alarm |
|
Protection |
Overload, Short circuits, Over/under input voltage, Over temperature |
|||
Operating TemperatureRange |
0°C to 45 °C |
|||
Dimensions (LxWxH) |
330 x 269 x 77 mm |
430 x 350 x 105 mm |
||
Net Weight |
4.9Kg |
8.5Kg |
8.5Kg |