Customization: | Available |
---|---|
Nature of Source Flow: | Active Inverter |
Certification: | CCC, ISO9001, CE |
Still deciding? Get samples of US$ 450/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Specifications | |||||
Model Parameters | GS1000W | GS2000W | GS2500W | GS3000W | |
AC Input |
Nominal Power | 1000W | 2000W | 2500W | 3000W |
Input Voltage Waveform | Sinusoidal (utility or generator) | ||||
Nominal input Voltage | 120/230VAC | ||||
Low Line Disconnect | 85Vac±4%(Normal) or 80Vac±4% (Wide) for 120V 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230V | ||||
High Line Disconnect | 136Vac±4%(Normal) or 140Vac±4%(Wide) for 120V 263Vac±4%(Normal) or 263Vac±4%(Wide) for 230V | ||||
Max AC input Voltage | 120V for Max150V, 230V for Max270V | ||||
Frequency | 50Hz:41-54Hz, 60Hz:51-64Hz | ||||
AC output |
Output Voltage Waveform | Sine wave | |||
Power Factor | 0.9~1.0 | ||||
Nominal Output Voltage (V) | LV:120Vac ±10%rms, HV:230Vac ±10%rms | ||||
Nominal Output Frequency (Hz) |
50Hz ± 0.3Hz, 50Hz ± 0.3Hz | ||||
Solar charger |
Rated Charge Current | 40A | 60A | ||
PV Input Voltage range | 15VDC-40VDC for 12VDC, 30VDC-55VDC for 24VDC, 60-110VDC for 48V | ||||
Max.PV open circuit array voltage |
12V for 40Vdc, 24V for 55Vdc, 48V for 110Vdc | ||||
Charger mode | MPPT | ||||
PV Low Voltage Re-connect |
PV≥Bat.V+3V | ||||
PV Low Voltage Disconnect |
PV<=Bat.V | ||||
Efficiency | ≥97% | ||||
AC Charger |
Nominal Charger Current |
35A/50A/70A/90A(According to the inverter model) | |||
5 stages adjustable charging current | |||||
Over charge Protection | Bat.V≥15.5VDC for 12V battery, Bat.V≥31.0VDC for 24V battery ,Bat.V≥62.0VDC for 48V battery beeps 0.5s every 1s & fault after 60s | ||||
Efficiency | Efficiency(Battery Mode) | ≥87% | |||
Efficiency (Line Mode) | >98% | ||||
Battery Voltage |
Nominal DC input Voltage | 12/24/48VDC | |||
Low Battery Alarm | 10.5VDC±0.3VDC for 12VDC | ||||
21VDC±0.6VDC for 24VDC | |||||
42VDC±1.2VDC for 48VDC | |||||
High DC input Alarm & Fault |
16VDC±0.3VDC for 12VDC | ||||
32VDC±0.6VDC for 24VDC | |||||
64VDC±1.2VDC for 48VDC | |||||
Transfer Time |
20ms(max) | ||||
System Parameter |
Over-Load Protection | 110%the output,load>150%, beeps 0.5s every 1s, and Fault after 20s | |||
Output Short Circuit Protection |
Current limit (Fault after 10s) | ||||
Surge Rating(10s) | 1:3(VA) | ||||
Power Saver | Load≤25W(Enabled on "P/S auto"Setting of Remote control) | ||||
Protections | Low battery, over charging, over load, over temp | ||||
General Specifications |
Operating Temperature Range |
0ºC~40ºC | |||
Storage Temperature | -15ºC~60ºC | ||||
Operation humidity | 5% to 95%(non-condensing) | ||||
Audible Noise | 60dB max | ||||
cooling | Forced air,variable speed fan | ||||
Dimension(L*W*H) | 480*336*190mm | ||||
Net Weight(kg) | 19.5 | 23.5 | 25.5 | 28 | |
Product specifications are subject to change without further notice |