Customization: | Available |
---|---|
Nature of Source Flow: | Active Inverter |
Phase: | Single |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Parameters Model | GW 1000W | GW 2000W | GW 2500W | GW 3000W | |
AC Input |
Nominal Power | 1000W | 2000W | 2500W | 3000W |
Input Voltage Waveform | Nominal input Voltage | ||||
Nominal input Voltage | 120/230Vac | ||||
Input Voltage Range | 70Vac-150Vac for 120Vac or 155Vac-270Vac for 230Vac | ||||
Low Line Disconnect | 93Vac±4% for 120Vac or 184Vac±4% for 230Vac | ||||
Low Line Re-connect | 98Vac±4% for 120Vac or 190Vac±4% for 230Vac | ||||
High Line Disconnect | 136Vac±4% for 120Vac or 263Vac±4% for 230Vac | ||||
Input AVR Range | 70Vac-93Vac for 120Vac or 155Vac-184Vac for 230Vac | ||||
Max AC input Voltage | 120V for Max150V, 230V for Max270V | ||||
Frequency | 50Hz:41-54Hz, 60Hz:51-64Hz | ||||
AC output |
Output Voltage Waveform | Sine wave | |||
Power Factor | 0.9~1.0 | ||||
Nominal Output Voltage (V) | LV:120Vac ±10%rms, HV:230Vac ±10%rms | ||||
Nominal Output Frequency (Hz) |
50Hz ± 0.3Hz, 60Hz ± 0.3Hz | ||||
AC Charger |
Nominal Charger Current |
20A/35A/50A/70A/90A(5 stages adjustable charging current) | |||
Over charge Protection | Bat.V≥15.5VDC for 12V battery, Bat.V≥31.0VDC for 24V battery, Bat.V≥62.0VDC for 48V battery, beeps 0.5s every 1s & fault after 60s | ||||
Efficiency | Efficiency (Battery Mode) | ≥85% | |||
Efficiency (Line Mode) | >98% | ||||
Battery Voltage |
Nominal DC input Voltage | 12/24/48VDC | |||
Low Battery Alarm | 10.5VDC±0.3VDC for 12VDC | ||||
21VDC±0.6VDC for 24VDC | |||||
42VDC±1.2VDC for 48VDC | |||||
40VDC±1.2VDC for 48VDC | |||||
High DC input Alarm & Fault |
16VDC±0.3VDC for 12VDC | ||||
32VDC±0.6VDC for 24VDC | |||||
64VDC±1.2VDC for 48VDC | |||||
Transfer Time | 20ms(max) | ||||
System Parameter |
Over-Load Protection | 110%<load<150% beeps 0.5s every 1s and Fault after 60s off the output,load>150% beeps 0.5s every 1s and Fault after 20s | |||
Output Short Circuit Protection | Current limit (Fault after 10s) | ||||
Surge Rating(10s) | 1:3(VA) | ||||
Protections | Low battery, over charging, over load, over temp | ||||
Indicators | LED+LCD Display | ||||
General Specifications |
Operating Temperature Range | 0ºC~40ºC | |||
Storage Temperature | -15ºC60ºC | ||||
Operation humidity | 5% to 95%(non-condensing) | ||||
Audible Noise | 60dB max | ||||
cooling | Forced air, variable speed fan | ||||
Dimension (L*W*H) |
475*242*182mm | ||||
Net Weight(kg) | 17.1 | 19.3 | 21.0 | 22.5 |