2u/3u 19" Rackmount Online UPS 1-10kVA LED Display

Product Details
Customization: Available
Phase: Single Phase
Type: On-line
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
100% Finished Products Inspection
The supplier inspects 100% of finished products.
R&D Capabilities
The supplier has 15 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
to see all verified strength labels (28)
  • 2u/3u 19" Rackmount Online UPS 1-10kVA LED Display
  • 2u/3u 19" Rackmount Online UPS 1-10kVA LED Display
  • 2u/3u 19" Rackmount Online UPS 1-10kVA LED Display
Find Similar Products

Basic Info.

Model NO.
RM1K -RM10K E
Protection
Short Circuit
Application
Communication
Classification
Lighting/Power
Standby Time
Long-acting Machine
Standby UPS
Sine Wave Output UPS
Output Capacity
Medium Type
Equipment Mode
Decentralized
Brand
Zlpower
Product Status
in Stock
Transport Package
Export Standard Package
Specification
CE
Trademark
ZLPOWER
Origin
Shenzhen
HS Code
8504402000
Production Capacity
3000PCS/Months

Product Description

1KVA~10KVA Rack mount High frequency online UPS is specially designed for servers, data-center critical network devices, sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, public security, ATM and so on.
 
Main Features:
1. True online double conversion technology with advanced microprocessor control
2. PWM Technology with IGBTS
3. LED Indicators display Detailed Real-Time UPS Status and parameters.
4. Set Output Voltage, Frequency parameter and bypass function on the display.
5. Advanced MCU microprocessor control technology, ensure long life reliability.
6. Wide input voltage range, Zero transfer time
7. Rack mount 19"design to save space
8. Excellent Protection against over voltage, over load, over current, over charge and so on.
9. Input L and N lines reverse wiring detection, Auto start when AC back.
10. DC start function, Input PFC revise function.
11. Humanization bypass output can be adjustable.
12. Smart RS232 communication with monitoring software.
13. Intelligent slot available for AS-400 Dry contact and SNMP card Remote control.
14. Strong antijamming capability.
15. Available to work with generators.
16. Lightning, surge, short circuit, Network/fax/modem surge protection.

Technical specification:
Rack Mount UPS ModelRM1KERM2KERM3KERM1KE-LRM2KE-LRM3KE-LRM6KE-LRM10KE-L
Rated PowerVA/W1kVA/ 0.7kW2kVA/ 1.4kW3kVA/ 2.1kW1kVA/ 0.7kW2kVA/ 1.4kW3kVA/ 2.1kW6kVA/ 4.8kW10Kva/ 8Kw
InputPhaseSingle Phase with Ground
Nominal Voltage110/115/120Vac or 220/230/240Vac220/230/240Vac
Voltage Range60-138VAC  or 115 ~ 300VAC176 ~ 276VAC
Frequency Range46 ~ 54Hz(default), user adjustable within 40~60Hz46 ~ 54Hz
Power Factor0.970.98
ConnectionIEC320-10A inletIEC320-16A inletIEC320-10A inletIEC320-16A inletTerminal Block
OutputPhaseSingle Phase
Voltage110/115/120Vac or 220/230/240VAC ± 2%110/115/120Vac or 220/230/240VAC± 1%
Frequency46~54Hz or 50Hz ± 0.2Hz (Line mode)46~54Hz (Line mode)
50Hz ± 0.2Hz ( Battery mode)50Hz ± 0.05Hz ( Battery mode)
WaveformPure Sine Wave
Overload Capability108%~150% for 30 sec., 150% for 300 ms105%~130% for 10 min.,130% for 1 min.
Current Crest Ratio3:1
ConnectionsIEC320 -10A * 4IEC320 -10A * 4IEC320-10A and Terminal BlockIEC320 -10A * 4IEC320 -10A * 4IEC320-10A and Terminal BlockIEC320-10A * 4 and Terminal Block
BypassAutomatic Transferon overload and UPS failure
Before UPS Power-onDefault "NO", user adjustable to "YES"Yes
Voltage Range 80~264VAC (Default), user adjustable within 80~286VAC176 ~ 261VAC
Transfer Time0 ms; less than 4 ms from inverter to bypass and vice versaZero
LED indicatorsLoad level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault
Audible AlarmBypass, On battery mode, Battery low, Overload, Fault
CommunicationsRS-232 Serial Interface
Intelligent Slot;
OPTIONS:  WEBPOWER SNMP/WEB card, AS400 card or WinPower CMC)
Network Surge ProtectionRJ45 I/O port available for network or Fax/Modem
EnvironmentalOperating Temperature0 ~ 40°C
Operating Humidity20 ~ 90% non-condensing
Main UnitNet Weight (Kg)16.310.311.29.111.512.318.320.3
Dimensions (L x W x H) mm482 x 420 x 88 (2U)600 x 482.6 x  130 (3U)
Battery PackTypeInternal BatteriesExternal Battery Pack
Nominal DC Voltage36VDC96VDC36VDC96VDC192VDC
Battery Numbers & Capacity3Pcs *12V7.2Ah8Pcs *12V7.2Ah8Pcs *12V7.2AhDepending on the capacity of external battery packs
Backup Time (Full load)     5 min9 min (with 1 BP)5 min (with 1 BP)
Recharge Time5hrs to 90%5hrs to 90%5hrs to 90%
Charging Current (Max.)1.0A1.0A1.0A8A±1A4.2A
Charging Voltage41.1Vdc±0.6V110Vdc±0.4V41.1Vdc±0.6V110Vdc±0.4V216Vdc±1%V
Net Weight (Kg)    ---25.325.3      ---      ---    ---               ---
Dimensions (L x W x H) mm          ---482 x 420 x88 (2U)482 x 420 x88 (2U)      ---      ---     ---               ---