Customization: | Available |
---|---|
Nature of Source Flow: | Active Inverter |
Certification: | ISO9001, CE, FCC |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL (GS Series) |
HV/LV Model | |||||||||
HV Model(4-10KW) LV Model(4-6KW) | ||||||||||
Line Mode Specifications: |
||||||||||
Input Voltage | Input Voltage Waveform | Sinusoidal (utility or generator) | ||||||||
Nominal Input Voltage | LV 120Vac | HV 230Vac | ||||||||
Low Line Disconnect | Normal:85Vac±4% Wide:80Vac±4% | Normal:184Vac±4% Wide:135Vac±4% | ||||||||
Low Line Re-connect | Normal:95Vac±4% Wide:85Vac±4% | Normal:194Vac±4% Wide:145Vac±4% | ||||||||
High Line Disconnect | Normal:136Vac±4% Wide:140Vac±4% | Normal:263Vac±4% Wide:263Vac±4% | ||||||||
High Line Re-connect | Normal:131Vac±4% Wide:135Vac±4% | Normal:253Vac±4% Wide:253Vac±4% | ||||||||
Max AC Input Voltage | 150Vrms | 270Vrms | ||||||||
Input Frequency | Nominal Input Frequency | 50Hz/ 60Hz (Auto detection) | ||||||||
Low Line Frequency Re-connect | 51+0.3Hz for 60Hz; 41+0.3Hz for 50Hz; |
|||||||||
Low Line Frequency Disconnect | 50+0.3Hz for 60Hz; 40+0.3Hz for 50Hz; |
|||||||||
High Line Frequency Re-connect | 64+0.3Hz for 60Hz; 54+0.3Hz for 50Hz; |
|||||||||
High Line Frequency Disconnect | 65+0.3Hz for 60Hz; 55+0.3Hz for 50Hz; |
|||||||||
main functions | Output Voltage Waveform | As same as Input Waveform | ||||||||
Over-Load Protection (SMPS load) | Air switch | |||||||||
Output Short Circuit Protection | Air switch | |||||||||
Max Bypass Overload Current | 40A/50A/80A | |||||||||
Battery Invert Mode Specifications: |
||||||||||
AC output | Output Voltage Waveform | Sine wave | ||||||||
Rated Output Power (KW) | LV:4KW/5KW/6KW | HV: 4KW/5KW/ 6KW/7KW/8KW/10KW |
||||||||
Power Factor | 0.9~1.0 | |||||||||
Nominal Output Voltage (V) | LV:120Vac ±10%rms | HV:230Vac ±10%rms | ||||||||
Nominal Output Frequency (Hz) | 60Hz ± 0.3Hz 50Hz ± 0.3Hz |
|||||||||
DC Voltage | Nominal DC Input Voltage | 24VDC/48VDC | ||||||||
DC Voltage range | 20-31.0Vdc for 24VDC 40-62.0Vdc for 48VDC |
|||||||||
Low Battery Alarm | 21.0Vdc ± 0.6Vdc for 24V battery 42.0Vdc ± 1.2Vdc for 48V battery |
|||||||||
Low DC input Shut-down | 20.0vdc± 0.6Vdc for 24V battery 40.0Vdc ± 1.2Vdc for 48V battery |
|||||||||
High DC input Alarm & Fault | 32Vdc ± 0.6Vdc for 24V battery 64Vdc ± 1.2Vdc for 48V battery |
|||||||||
High DC input Recovery | 31.0Vdc ± 0.6Vdc for 24V battery 62.0Vdc ± 1.2Vdc for 48V battery |
|||||||||
AC Charger | Nominal Charge Current | 35A/50A/70A (5 stages adjustable charging current) | ||||||||
Charge Current Regulation | ± 5Adc | |||||||||
Over Charge Protection | Bat.V≥31.0VDC for 24V battery Bat.V≥62.0VDC for 48V battery beeps 0.5s every 1s & fault after 60s |
|||||||||
Algorithm | Three stage: Boost CC (constant current stage) → Boost CV (constant voltage stage) → Float (constant voltage stage) | |||||||||
Solar charger | Rated Charge Current | 40A | 60A | |||||||
Rated charge battery Voltage type | 24V/48V | 24V | ||||||||
Max.PV open circuit array voltage | 24V for 55Vdc 48V for 110Vdc |
|||||||||
Charger mode | MPPT | |||||||||
PV Low Voltage Re-connect | PV≥Bat.V=3V | |||||||||
PV Low Voltage Disconnect | PV<=Bat.V | |||||||||
Efficiency | ≥97% | |||||||||
Efficiency | Efficiency (Battery Mode) | ≥85% | ||||||||
Efficiency (Line Mode) | >98% | |||||||||
Transfer Time | Ac to Dc | 20ms (Max) | ||||||||
Dc to Ac | 15ms (Max) | |||||||||
System parameter | Over-Load Protection | 110% <load<150%, beeps 0.5s every 1s, and Fault after 60s off the output, Load>150%, beeps 0.5s every 1s, and Fault after 20s. | ||||||||
Output Short Circuit Protection | Current limit (Fault after 10s) | |||||||||
Surge rating (10s) | 1:3 (VA) | |||||||||
Power saver | Load <=25W (Enabled on "P/S auto" setting of Remote control) | |||||||||
Protections | Low battery, over charging, over load , over temp. | |||||||||
Indicators | LED+LCD Display | |||||||||
General Specifications | Operating Temperature Range | 0°C to 40°C | ||||||||
Storage temperature | -15ºC ~60ºC | |||||||||
Operation humidity | 5% to 95%(non-condensing) | |||||||||
Audible Noise | 60dB max | |||||||||
Cooling | Forced air, variable speed fan | |||||||||
Dimension(L*W*H) | 4KW | 5KW | 6KW | 7KW | 8KW | 10KW | ||||
530*400*190mm | 590*420*195mm | |||||||||
Net weight(Kg) | 30.0 | 35.5 | 38.5 | 41.5 | 48.0 | 55.0 |
MODEL (GW Series) |
HV/LV Model | ||||||||
HV Model(1-12KW) LV Model(1-6KW) | |||||||||
Line Mode Specifications: |
|||||||||
Input Voltage | Input Voltage Waveform | Sinusoidal (utility or generator) | |||||||
Nominal Input Voltage | LV 120Vac | HV 230Vac | |||||||
Low Line Disconnect | Normal:85Vac±4% Wide:80Vac±4% | Normal:184Vac±4% Wide:135Vac±4% | |||||||
Low Line Re-connect | Normal:95Vac±4% Wide:85Vac±4% | Normal:194Vac±4% Wide:145Vac±4% | |||||||
High Line Disconnect | Normal:136Vac±4% Wide:140Vac±4% | Normal:263Vac±4% Wide:263Vac±4% | |||||||
High Line Re-connect | Normal:131Vac±4% Wide:135Vac±4% | Normal:253Vac±4% Wide:253Vac±4% | |||||||
Max AC Input Voltage | 150Vrms | 270Vrms | |||||||
Input Frequency | Nominal Input Frequency | 50Hz/ 60Hz (Auto detection) | |||||||
Low Line Frequency Re-connect | 51+0.3Hz for 60Hz; 41+0.3Hz for 50Hz; |
||||||||
Low Line Frequency Disconnect | 50+0.3Hz for 60Hz; 40+0.3Hz for 50Hz; |
||||||||
High Line Frequency Re-connect | 64+0.3Hz for 60Hz; 54+0.3Hz for 50Hz; |
||||||||
High Line Frequency Disconnect | 65+0.3Hz for 60Hz; 55+0.3Hz for 50Hz; |
||||||||
main functions | Output Voltage Waveform | As same as Input Waveform | |||||||
Over-Load Protection (SMPS load) | Air switch | ||||||||
Output Short Circuit Protection | Air switch | ||||||||
Max Bypass Overload Current | 30A/40A/50A | ||||||||
Battery Invert Mode Specifications: |
|||||||||
output | Output Voltage Waveform | Sine wave | |||||||
Rated Output Power (KW) | LV:1~6KW | HV: 1~12KW | |||||||
Power Factor | 0.9~1.0 | ||||||||
Nominal Output Voltage (V) | LV:120Vac ±10%rms | HV:230Vac ±10%rms | |||||||
Nominal Output Frequency (Hz) | 60Hz ± 0.3Hz 50Hz ± 0.3Hz |
||||||||
DC Voltage | Nominal DC Input Voltage | 12VDC/24VDC/48VDC | |||||||
DC Voltage range | 10-15.5Vdc for 12VDC 20-31.0Vdc for 24VDC 40-62.0Vdc for 48VDC |
||||||||
Low Battery Alarm | 10.5Vdc ± 0.3Vdc for 12V battery 21.0Vdc ± 0.6Vdc for 24V battery 42.0Vdc ± 1.2Vdc for 48V battery |
||||||||
Low DC input Shut-down | 10.0Vdc ± 0.3Vdc for 12V battery 20.0vdc± 0.6Vdc for 24V battery 40.0Vdc ± 1.2Vdc for 48V battery |
||||||||
High DC input Alarm & Fault | 16Vdc ± 0.3Vdc for 12V battery 32Vdc ± 0.6Vdc for 24V battery 64Vdc ± 1.2Vdc for 48V battery |
||||||||
High DC input Recovery | 15.5Vdc ± 0.3Vdc for 12V battery 31.0Vdc ± 0.6Vdc for 24V battery 62.0Vdc ± 1.2Vdc for 48V battery |
||||||||
AC Charger | Nominal Charge Current | 20A/35A/50A/70A/90A(5 stages adjustable charging current) | |||||||
Charge Current Regulation | ± 5Adc | ||||||||
Over Charge Protection | Bat.V≥15.5VDC for 12V battery Bat.V≥31.0VDC for 24V battery Bat.V≥62.0VDC for 48V battery beeps 0.5s every 1s & fault after 60s |
||||||||
Algorithm | Three stage: Boost CC (constant current stage) → Boost CV (constant voltage stage) → Float (constant voltage stage) | ||||||||
Solar charger | Rated Charge Current | 40A | 60A | ||||||
Rated charge battery Voltage type | 12V/24V/48V | 12V/24V | |||||||
Max.PV open circuit array voltage | 12V for 40Vdc 24V for 55Vdc 48V for 110Vdc |
||||||||
Charger mode | MPPT | ||||||||
PV Low Voltage Re-connect | PV≥Bat.V=3V | ||||||||
PV Low Voltage Disconnect | PV<=Bat.V | ||||||||
Efficiency | ≥97% | ||||||||
Efficiency | Efficiency (Battery Mode) | ≥85% | |||||||
Efficiency (Line Mode) | >98% | ||||||||
Transfer Time | Ac to Dc | 20ms (Max) | |||||||
Dc to Ac | 15ms (Max) | ||||||||
System parameter | Over-Load Protection | 110% <load<150%, beeps 0.5s every 1s, and Fault after 60s off the output, Load>150%, beeps 0.5s every 1s, and Fault after 20s. | |||||||
Output Short Circuit Protection | Current limit (Fault after 10s) | ||||||||
Surge rating (10s) | 1:3 (VA) | ||||||||
Power saver | Load <=25W (Enabled on "P/S auto" setting of Remote control) | ||||||||
Protections | Low battery, over charging, over load , over temp. | ||||||||
Indicators | LED+LCD Display | ||||||||
General Specifications | Operating Temperature Range | 0°C to 40°C | |||||||
Storage temperature | -15ºC ~60ºC | ||||||||
Operation humidity | 5% to 95%(non-condensing) | ||||||||
Audible Noise | 60dB max | ||||||||
Cooling | Forced air, variable speed fan | ||||||||
Dimension(L*W*H) | 3KW | 5KW | 6KW | 8KW | 10KW | 12KW | |||
Net weight(Kg) |