Rack Mount UPS Model |
RM1K |
RM2K |
RM3K |
RM1K-L |
RM2K-L |
RM3K-L |
RM6K-L |
RM10K-L |
Rated Power |
VA/W |
1KVA/800W |
2KVA/1600W |
3KVA/2400W |
1KVA/800W |
2KVA/1600W |
3KVA/2400W |
6KVA/4800W |
10KVA/8000W |
Input |
Phase |
Single Phase with Ground |
Nominal Voltage |
110/115/120Vac or 220/230/240Vac |
220/230/240Vac |
Voltage Range |
60-138VAC or 115 ~ 300VAC |
176 ~ 276VAC |
Frequency Range |
46 ~ 54Hz(default), user adjustable within 40~60Hz |
46 ~ 54Hz |
Power Factor |
0.97 |
0.98 |
Connection |
IEC320-10A inlet |
IEC320-16A inlet |
IEC320-10A inlet |
IEC320-16A inlet |
Terminal Block |
Output |
Phase |
Single Phase |
Voltage |
110/115/120Vac or 220/230/240VAC ± 2% |
110/115/120Vac or 220/230/240VAC± 1% |
Frequency |
46~54Hz or 50Hz ± 0.2Hz (Line mode) |
46~54Hz (Line mode) |
50Hz ± 0.2Hz ( Battery mode) |
50Hz ± 0.05Hz ( Battery mode) |
Waveform |
Pure Sine Wave |
Overload Capability |
108%~150% for 30 sec., 150% for 300 ms |
105%~130% for 10 min.,130% for 1 min. |
Current Crest Ratio |
3:1 |
Connections |
IEC320 -10A * 4 |
IEC320 -10A * 4 |
IEC320-10A and Terminal Block |
IEC320 -10A * 4 |
IEC320 -10A * 4 |
IEC320-10A and Terminal Block |
IEC320-10A * 4 and Terminal Block |
Bypass |
Automatic Transfer |
on overload and UPS failure |
Before UPS Power-on |
Default "NO", user adjustable to "YES" |
Yes |
Voltage Range |
80~264VAC (Default), user adjustable within 80~286VAC |
176 ~ 261VAC |
Transfer Time |
0 ms; less than 4 ms from inverter to bypass and vice versa |
Zero |
LED indicators |
Load level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault |
Audible Alarm |
Bypass, On battery mode, Battery low, Overload, Fault |
Communications |
RS-232 Serial Interface |
Intelligent Slot; |
OPTIONS: WEBPOWER SNMP/WEB card, AS400 card or WinPower CMC) |
Network Surge Protection |
RJ45 I/O port available for network or Fax/Modem |
Environmental |
Operating Temperature |
0 ~ 40°C |
Operating Humidity |
20 ~ 90% non-condensing |
Main Unit |
Net Weight (Kg) |
16.3 |
10.3 |
11.2 |
9.1 |
11.5 |
12.3 |
18.3 |
20.3 |
Dimensions (L x W x H) mm |
482 x 420 x 88 (2U) |
600 x 482.6 x 130 (3U) |
Battery Pack |
Type |
Internal Batteries |
External Battery Pack |
Nominal DC Voltage |
36VDC |
96VDC |
36VDC |
96VDC |
192VDC |
Battery Numbers & Capacity |
3Pcs *12V7.2Ah |
8Pcs *12V7.2Ah |
8Pcs *12V7.2Ah |
Depending on the capacity of external battery packs |
Backup Time (Full load) |
5 min |
9 min (with 1 BP) |
5 min (with 1 BP) |
Recharge Time |
5hrs to 90% |
5hrs to 90% |
5hrs to 90% |
Charging Current (Max.) |
1.0A |
1.0A |
1.0A |
8A±1A |
4.2A |
Charging Voltage |
41.1Vdc±0.6V |
110Vdc±0.4V |
41.1Vdc±0.6V |
110Vdc±0.4V |
216Vdc±1%V |
Net Weight (Kg) |
--- |
25.3 |
25.3 |
--- |
--- |
--- |
--- |
Dimensions (L x W x H) mm |
--- |
482 x 420 x88 (2U) |
482 x 420 x88 (2U) |
--- |
--- |
--- |
--- |